Preliminary experience on the safety and tolerability of mechanical "insufflation-exsufflation" in subjects with artificial airway.


ABSTRACT: BACKGROUND:Catheter suctioning of respiratory secretions in intubated subjects is limited to the proximal airway and associated with traumatic lesions to the mucosa and poor tolerance. "Mechanical insufflation-exsufflation" exerts positive pressure, followed by an abrupt drop to negative pressure. Potential advantages of this technique are aspiration of distal airway secretions, avoiding trauma, and improving tolerance. METHODS:We applied insufflation of 50 cmH2O for 3 s and exsufflation of -?45 cmH2O for 4 s in patients with an endotracheal tube or tracheostomy cannula requiring secretion suctioning. Cycles of 10 to 12 insufflations-exsufflations were performed and repeated if secretions were aspirated and visible in the proximal artificial airway. Clinical and laboratory parameters were collected before and 5 and 60 min after the procedure. Subjects were followed during their ICU stay until discharge or death. RESULTS:Mechanical insufflation-exsufflation was applied 26 times to 7 male and 6 female subjects requiring suctioning. Mean age was 62.6?±?20 years and mean Apache II score 23.3?±?7.4 points. At each session, a median of 2 (IQR 1; 2) cycles on median day of intubation 11.5 (IQR 6.25; 25.75) were performed. Mean insufflation tidal volume was 1043.6?±?649.9 ml. No statistically significant differences were identified between baseline and post-procedure time points. Barotrauma, desaturation, atelectasis, hemoptysis, or other airway complication and hemodynamic complications were not detected. All, except one, of the mechanical insufflation-exsufflation sessions were productive, showing secretions in the proximal artificial airway, and were well tolerated. CONCLUSIONS:Our preliminary data suggest that mechanical insufflation-exsufflation may be safe and effective in patients with artificial airway. Safety and efficacy need to be confirmed in larger studies with different patient populations. TRIAL REGISTRATION:EudraCT 2017-005201-13 (EU Clinical Trials Register).

SUBMITTER: Sanchez-Garcia M 

PROVIDER: S-EPMC5882479 | biostudies-literature | 2018 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>Catheter suctioning of respiratory secretions in intubated subjects is limited to the proximal airway and associated with traumatic lesions to the mucosa and poor tolerance. "Mechanical insufflation-exsufflation" exerts positive pressure, followed by an abrupt drop to negative pressure. Potential advantages of this technique are aspiration of distal airway secretions, avoiding trauma, and improving tolerance.<h4>Methods</h4>We applied insufflation of 50 cmH<sub>2</sub>O for 3   ...[more]

Similar Datasets

| S-EPMC7013176 | biostudies-literature
| S-EPMC5137572 | biostudies-literature
| S-EPMC8048789 | biostudies-literature
| S-EPMC7724723 | biostudies-literature
| S-EPMC8662824 | biostudies-literature
| S-EPMC10364411 | biostudies-literature
| S-EPMC7496261 | biostudies-literature
| S-EPMC6175428 | biostudies-literature
| S-EPMC6267549 | biostudies-literature
2023-07-24 | GSE237965 | GEO