Opto-mechanical lab-on-fibre seismic sensors detected the Norcia earthquake.


ABSTRACT: We have designed and developed lab-on-fibre seismic sensors containing a micro-opto-mechanical cavity on the fibre tip. The mechanical cavity is designed as a double cantilever suspended on the fibre end facet and connected to a proof mass to tune its response. Ground acceleration leads to displacement of the cavity length, which in turn can be remotely detected using an interferometric interrogation technique. After the sensors characterization, an experimental validation was conducted at the Italian National Institute of Geophysics and Volcanology (INGV), which is responsible for seismic surveillance over the Italian country. The fabricated sensors have been continuously used for long periods to demonstrate their effectiveness as seismic accelerometer sensors. During the tests, fibre optic seismic accelerometers clearly detected the seismic sequence that culminated in the severe Mw6.5 Norcia earthquake that struck central Italy on October 30, 2016. The seismic data provided by the optical sensors were analysed by specialists at the INGV. The wave traces were compared with state-of-the-art traditional sensors typically incorporated into the INGV seismic networks. The comparison verifies the high fidelity of the optical sensors in seismic wave detection, indicating their suitability for a novel class of seismic sensors to be employed in practical scenarios.

SUBMITTER: Pisco M 

PROVIDER: S-EPMC5923338 | biostudies-literature | 2018 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Opto-mechanical lab-on-fibre seismic sensors detected the Norcia earthquake.

Pisco Marco M   Bruno Francesco Antonio FA   Galluzzo Danilo D   Nardone Lucia L   Gruca Grzegorz G   Rijnveld Niek N   Bianco Francesca F   Cutolo Antonello A   Cusano Andrea A  

Scientific reports 20180427 1


We have designed and developed lab-on-fibre seismic sensors containing a micro-opto-mechanical cavity on the fibre tip. The mechanical cavity is designed as a double cantilever suspended on the fibre end facet and connected to a proof mass to tune its response. Ground acceleration leads to displacement of the cavity length, which in turn can be remotely detected using an interferometric interrogation technique. After the sensors characterization, an experimental validation was conducted at the I  ...[more]

Similar Datasets

| S-EPMC6414550 | biostudies-literature
| S-EPMC7267715 | biostudies-literature
| S-EPMC5601465 | biostudies-literature
| S-EPMC7512422 | biostudies-literature
| S-EPMC5870340 | biostudies-literature
| S-EPMC4758737 | biostudies-literature
| S-EPMC8639099 | biostudies-literature
| S-EPMC5242500 | biostudies-literature
| S-EPMC5010128 | biostudies-literature
| S-EPMC8052401 | biostudies-literature