True Tapping Mode Scanning Near-Field Optical Microscopy with Bent Glass Fiber Probes.


ABSTRACT: In scanning near-field optical microscopy, the most popular probes are made of sharpened glass fiber attached to a quartz tuning fork (TF) and exploiting the shear force-based feedback. The use of tapping mode feedback could be preferable. Such an approach can be realized, for example, using bent fiber probes. Detailed analysis of fiber vibration modes shows that realization of truly tapping mode of the probe dithering requires an extreme caution. In case of using the second resonance mode, probes vibrate mostly in shear force mode unless the bending radius is rather small (ca. 0.3?mm) and the probe's tip is short. Otherwise, the shear force character of the dithering persists. Probes having these characteristics were prepared by irradiation of a tapered etched glass fiber with a CW CO2 laser. These probes were attached to the TF in double resonance conditions which enables achieving significant quality factor (4000-6000) of the TF + probe system (Cherkun et al., 2006). We also show that, to achieve a truly tapping character, dithering, short, and not exceeding 3?mm lengths of a freestanding part of bent fiber probe beam should also be used in the case of nonresonant excitation.

SUBMITTER: Smirnov A 

PROVIDER: S-EPMC5937387 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

True Tapping Mode Scanning Near-Field Optical Microscopy with Bent Glass Fiber Probes.

Smirnov A A   Yasinskii V M VM   Filimonenko D S DS   Rostova E E   Dietler G G   Sekatskii S K SK  

Scanning 20180422


In scanning near-field optical microscopy, the most popular probes are made of sharpened glass fiber attached to a quartz tuning fork (TF) and exploiting the shear force-based feedback. The use of tapping mode feedback could be preferable. Such an approach can be realized, for example, using bent fiber probes. Detailed analysis of fiber vibration modes shows that realization of truly tapping mode of the probe dithering requires an extreme caution. In case of using the second resonance mode, prob  ...[more]

Similar Datasets

| S-EPMC5962580 | biostudies-literature
| S-EPMC10113767 | biostudies-literature
| S-EPMC4278694 | biostudies-literature
| S-EPMC7162806 | biostudies-literature
| S-EPMC6482031 | biostudies-literature
| S-EPMC5700110 | biostudies-literature
| S-EPMC6955111 | biostudies-literature
| S-EPMC8992282 | biostudies-literature
| S-EPMC4673874 | biostudies-literature
| S-EPMC10311587 | biostudies-literature