Thermo-Acoustic Ultrasound for Detection of RF-Induced Device Lead Heating in MRI.


ABSTRACT: Patients who have implanted medical devices with long conductive leads are often restricted from receiving MRI scans due to the danger of RF-induced heating near the lead tips. Phantom studies have shown that this heating varies significantly on a case-by-case basis, indicating that many patients with implanted devices can receive clinically useful MRI scans without harm. However, the difficulty of predicting RF-induced lead tip heating prior to scanning prevents numerous implant recipients from being scanned. Here, we demonstrate that thermo-acoustic ultrasound (TAUS) has the potential to be utilized for a pre-scan procedure assessing the risk of RF-induced lead tip heating in MRI. A system was developed to detect TAUS signals by four different TAUS acquisition methods. We then integrated this system with an MRI scanner and detected a peak in RF power absorption near the tip of a model lead when transmitting from the scanner's body coil. We also developed and experimentally validated simulations to characterize the thermo-acoustic signal generated near lead tips. These results indicate that TAUS is a promising method for assessing RF implant safety, and with further development, a TAUS pre-scan could allow many more patients to have access to MRI scans of significant clinical value.

SUBMITTER: Dixit N 

PROVIDER: S-EPMC5942199 | biostudies-literature | 2018 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Thermo-Acoustic Ultrasound for Detection of RF-Induced Device Lead Heating in MRI.

Dixit Neerav N   Stang Pascal P PP   Pauly John M JM   Scott Greig C GC  

IEEE transactions on medical imaging 20171018 2


Patients who have implanted medical devices with long conductive leads are often restricted from receiving MRI scans due to the danger of RF-induced heating near the lead tips. Phantom studies have shown that this heating varies significantly on a case-by-case basis, indicating that many patients with implanted devices can receive clinically useful MRI scans without harm. However, the difficulty of predicting RF-induced lead tip heating prior to scanning prevents numerous implant recipients from  ...[more]

Similar Datasets

| S-EPMC6475594 | biostudies-literature
| S-EPMC7047541 | biostudies-literature
| S-EPMC6702128 | biostudies-literature
| S-EPMC6579539 | biostudies-literature
| S-EPMC5814144 | biostudies-other
| S-EPMC6033924 | biostudies-literature
| S-EPMC6746718 | biostudies-literature
| S-EPMC8433187 | biostudies-literature
| S-EPMC3285652 | biostudies-literature
| S-EPMC7562700 | biostudies-literature