Ontology highlight
ABSTRACT: Background
Size mismatch between donor lungs and a recipient thorax could affect the major determinants of maximal expiratory airflow: airway resistance, propensity of airways to collapse, and lung elastic recoil.Methods
A retrospective review of 159 adults who received bilateral lung transplants was performed. The predicted total lung capacity (pTLC) for donors and recipients was calculated based on sex and height. Size matching was represented using the following formula: pTLC ratio = donor pTLC / recipient pTLC. Patients were grouped according to those with a pTLC ratio > 1.0 (oversized) or those with a pTLC ratio ? 1.0 (undersized). Allograft function was analyzed in relation to the pTLC ratio and to recipient and donor predicted function.Results
The 96 patients in the oversized cohort had a mean pTLC ratio of 1.16 ± 0.13 vs 0.89 ± 0.09 in the 63 patients of the undersized group. At 1 to 6 months posttransplant, the patients in the oversized cohort had higher FEV(1)/FVC ratios (0.895 ± 0.13 vs 0.821 ± 0.13, P < .01) and lower time constant estimates of lung emptying (0.38 ± 0.2 vs 0.64 ± 0.4, P < .01) than patients in the undersized cohort. Although the FVCs expressed as % predicted for the recipient were not different between cohorts, the FVCs expressed as % predicted for the donor organ were lower in the oversized cohort compared with the undersized cohort (at 1-6 months, 52.4% ± 17.1% vs 65.3% ± 18.3%, P < .001). Kaplan-Meier estimates for the occurrence of bronchiolitis obliterans syndrome (BOS) showed that patients in the oversized cohort had a lower probability of BOS (P < .001).Conclusions
A pTLC ratio > 1.0, suggestive of an oversized allograft, is associated with higher expiratory airflow capacity and a less frequent occurrence of BOS.
SUBMITTER: Eberlein M
PROVIDER: S-EPMC5991546 | biostudies-literature | 2012 Feb
REPOSITORIES: biostudies-literature
Eberlein Michael M Permutt Solbert S Chahla Mayy F MF Bolukbas Servet S Nathan Steven D SD Shlobin Oksana A OA Shelhamer James H JH Reed Robert M RM Pearse David B DB Orens Jonathan B JB Brower Roy G RG
Chest 20110728 2
<h4>Background</h4>Size mismatch between donor lungs and a recipient thorax could affect the major determinants of maximal expiratory airflow: airway resistance, propensity of airways to collapse, and lung elastic recoil.<h4>Methods</h4>A retrospective review of 159 adults who received bilateral lung transplants was performed. The predicted total lung capacity (pTLC) for donors and recipients was calculated based on sex and height. Size matching was represented using the following formula: pTLC ...[more]