Unknown

Dataset Information

0

High-content imaging assays on a miniaturized 3D cell culture platform.


ABSTRACT: The majority of high-content imaging (HCI) assays have been performed on two-dimensional (2D) cell monolayers for its convenience and throughput. However, 2D-cultured cell models often do not represent the in vivo characteristics accurately and therefore reduce the predictability of drug toxicity/efficacy in vivo. Recently, three-dimensional (3D) cell-based HCI assays have been demonstrated to improve predictability, but its use is limited due to difficulty in maneuverability and low throughput in cell imaging. To alleviate these issues, we have developed miniaturized 3D cell culture on a micropillar/microwell chip and demonstrated high-throughput HCI assays for mechanistic toxicity. Briefly, Hep3B human hepatoma cell line was encapsulated in a mixture of alginate and fibrin gel on the micropillar chip, cultured in 3D, and exposed to six model compounds in the microwell chip for rapidly assessing mechanistic hepatotoxicity. Several toxicity parameters, including DNA damage, mitochondrial impairment, intracellular glutathione level, and cell membrane integrity were measured on the chip, and the IC50 values of the compounds at different readouts were determined to investigate the mechanism of toxicity. Overall, the Z' factors were between 0.6 and 0.8 for the HCI assays, and the coefficient of variation (CV) were below 20%. These results indicate high robustness and reproducibility of the HCI assays established on the miniaturized 3D cell culture chip. In addition, it was possible to determine the predominant mechanism of toxicity using the 3D HCI assays. Therefore, our miniaturized 3D cell culture coupled with HCI assays has great potential for high-throughput screening (HTS) of compounds and mechanistic toxicity profiling.

SUBMITTER: Joshi P 

PROVIDER: S-EPMC5994365 | biostudies-literature | 2018 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

High-content imaging assays on a miniaturized 3D cell culture platform.

Joshi Pranav P   Datar Akshata A   Yu Kyeong-Nam KN   Kang Soo-Yeon SY   Lee Moo-Yeal MY  

Toxicology in vitro : an international journal published in association with BIBRA 20180306


The majority of high-content imaging (HCI) assays have been performed on two-dimensional (2D) cell monolayers for its convenience and throughput. However, 2D-cultured cell models often do not represent the in vivo characteristics accurately and therefore reduce the predictability of drug toxicity/efficacy in vivo. Recently, three-dimensional (3D) cell-based HCI assays have been demonstrated to improve predictability, but its use is limited due to difficulty in maneuverability and low throughput  ...[more]

Similar Datasets

| S-EPMC6347521 | biostudies-literature
| S-EPMC4594878 | biostudies-literature
| S-EPMC3894557 | biostudies-literature
| S-EPMC7074014 | biostudies-literature
| S-EPMC6032403 | biostudies-literature
| S-EPMC5593641 | biostudies-literature
| S-EPMC4556086 | biostudies-literature
| S-EPMC5030728 | biostudies-literature
| S-EPMC6451746 | biostudies-literature
| S-TOXR1192 | biostudies-other