Unknown

Dataset Information

0

Toward Point-of-Care Drug Quality Assurance in Developing Countries: Comparison of Liquid Chromatography and Infrared Spectroscopy Quantitation of a Small-Scale Random Sample of Amoxicillin.


ABSTRACT: Substandard antibiotics are thought to be a major threat to public health in developing countries and a cause of antimicrobial resistance. However, assessing quality outside of a laboratory setting, using simple equipment, is challenging. The aim of this study was to validate the use of a portable Fourier transform infrared (FT-IR) spectrometer for the identification of substandard antibiotics. Results are presented for amoxicillin packages from Haiti, Ghana, Sierra Leone, Democratic Republic of Congo, India, Papua New Guinea, and Ethiopia collected over the course of 6 months in 2017, including two field trips with the FT-IR to Ghana and Sierra Leone. Canadian samples were used as a control. Regarding drug quality, of 290 individual capsules of amoxicillin analyzed, 13 were found to be substandard with total active pharmaceutical ingredients (API) lying outside the acceptable range of 90-110%. Of these 13, four were below 80% API. The FT-IR reliably identified these outliers and was found to yield results in good agreement with the established pharmacopeia liquid chromatography protocol. We conclude that the portable FT-IR may be suitable to intercept substandard antibiotics in developing countries where more sophisticated techniques are not readily available.

SUBMITTER: Alotaibi N 

PROVIDER: S-EPMC6090331 | biostudies-literature | 2018 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Toward Point-of-Care Drug Quality Assurance in Developing Countries: Comparison of Liquid Chromatography and Infrared Spectroscopy Quantitation of a Small-Scale Random Sample of Amoxicillin.

Alotaibi Norah N   Overton Sean S   Curtis Sharon S   Nickerson Jason W JW   Attaran Amir A   Gilmer Sheldon S   Mayer Paul M PM  

The American journal of tropical medicine and hygiene 20180607 2


Substandard antibiotics are thought to be a major threat to public health in developing countries and a cause of antimicrobial resistance. However, assessing quality outside of a laboratory setting, using simple equipment, is challenging. The aim of this study was to validate the use of a portable Fourier transform infrared (FT-IR) spectrometer for the identification of substandard antibiotics. Results are presented for amoxicillin packages from Haiti, Ghana, Sierra Leone, Democratic Republic of  ...[more]

Similar Datasets

| S-EPMC6361725 | biostudies-literature
| S-EPMC8252148 | biostudies-literature
| S-EPMC7379868 | biostudies-literature
| S-EPMC10103134 | biostudies-literature
| S-EPMC6023859 | biostudies-literature
| S-EPMC3832181 | biostudies-literature
| S-EPMC7304664 | biostudies-literature
| S-EPMC2745394 | biostudies-literature
| S-EPMC9496531 | biostudies-literature
2024-02-26 | PXD046796 | Pride