An error-aware gaze-based keyboard by means of a hybrid BCI system.


ABSTRACT: Gaze-based keyboards offer a flexible way for human-computer interaction in both disabled and able-bodied people. Besides their convenience, they still lead to error-prone human-computer interaction. Eye tracking devices may misinterpret user's gaze resulting in typesetting errors, especially when operated in fast mode. As a potential remedy, we present a novel error detection system that aggregates the decision from two distinct subsystems, each one dealing with disparate data streams. The first subsystem operates on gaze-related measurements and exploits the eye-transition pattern to flag a typo. The second, is a brain-computer interface that utilizes a neural response, known as Error-Related Potentials (ErrPs), which is inherently generated whenever the subject observes an erroneous action. Based on the experimental data gathered from 10 participants under a spontaneous typesetting scenario, we first demonstrate that ErrP-based Brain Computer Interfaces can be indeed useful in the context of gaze-based typesetting, despite the putative contamination of EEG activity from the eye-movement artefact. Then, we show that the performance of this subsystem can be further improved by considering also the error detection from the gaze-related subsystem. Finally, the proposed bimodal error detection system is shown to significantly reduce the typesetting time in a gaze-based keyboard.

SUBMITTER: Kalaganis FP 

PROVIDER: S-EPMC6123473 | biostudies-literature | 2018 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

An error-aware gaze-based keyboard by means of a hybrid BCI system.

Kalaganis Fotis P FP   Chatzilari Elisavet E   Nikolopoulos Spiros S   Kompatsiaris Ioannis I   Laskaris Nikos A NA  

Scientific reports 20180904 1


Gaze-based keyboards offer a flexible way for human-computer interaction in both disabled and able-bodied people. Besides their convenience, they still lead to error-prone human-computer interaction. Eye tracking devices may misinterpret user's gaze resulting in typesetting errors, especially when operated in fast mode. As a potential remedy, we present a novel error detection system that aggregates the decision from two distinct subsystems, each one dealing with disparate data streams. The firs  ...[more]

Similar Datasets

| S-EPMC4131427 | biostudies-other
| S-EPMC5474280 | biostudies-literature
| S-EPMC5564129 | biostudies-literature
| S-EPMC5536819 | biostudies-other
| S-EPMC5011245 | biostudies-literature
| S-EPMC7355841 | biostudies-literature
| S-EPMC7755477 | biostudies-literature
| S-EPMC7766128 | biostudies-literature
| S-EPMC7288752 | biostudies-literature