Optimizing diagnostic biomarkers of iron deficiency anemia in community-dwelling Indian women and preschool children.


ABSTRACT: The detection of iron deficiency anemia is challenged by the paucity of diagnostic tests demonstrating high sensitivity and specificity. Using two biomarkers, zinc-protoporphyrin/heme and hepcidin, we established the diagnostic cut-off values for iron deficiency anemia in preschool children and women. We randomly selected non-anemic individuals (n=190; women=90, children=100) and individuals with iron deficiency anemia (n=200; women=100, children=100) from a preexisting cohort of healthy preschool children and their mothers. The diagnostic performance of these biomarkers was estimated by analyzing receiver operating characteristic curves. Diagnostic cut-offs with a high predictive value for iron deficiency anemia were selected. Median zinc-protoporphyrin/heme and hepcidin values in non-anemic children were 49 ?mol/mol heme and 42 ng/mL, respectively, and in non-anemic women these values were 66 ?mol/mol heme and 17.7ng/mL, respectively. Children and women with iron deficiency anemia had higher zinc-protoporphyrin/heme ratios (children=151 ?mol/mol heme and women=155 ?mol/mol heme) and lower hepcidin levels (children=1.2ng/mL and women=0.6ng/mL). A zinc-protoporphyrin/heme ratio cut-off >90 ?mole/mole heme in children and >107 ?mole/mole heme in women was associated with a high diagnostic likelihood for iron deficiency anemia (children, likelihood ratio=20.2: women, likelihood ratio=10.8). Hepcidin cut-off values of ?6.8ng/mL in children and ?4.5ng/mL in women were associated with a high diagnostic likelihood for iron deficiency anemia (children, likelihood ratio=14.3: women, likelihood ratio=16.2). The reference ranges and cut-off values identified in this study provide clinicians with guidance for applying these tests to detect iron deficiency anemia. Erythrocyte zinc-protoporphyrin/heme ratio is a valid point-of-care biomarker to diagnose iron deficiency anemia.

SUBMITTER: Kanuri G 

PROVIDER: S-EPMC6269316 | biostudies-literature | 2018 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Optimizing diagnostic biomarkers of iron deficiency anemia in community-dwelling Indian women and preschool children.

Kanuri Giridhar G   Chichula Deepti D   Sawhney Ritica R   Kuriakose Kevin K   De'Souza Sherwin S   Pais Faye F   Arumugam Karthika K   Shet Arun S AS  

Haematologica 20180809 12


The detection of iron deficiency anemia is challenged by the paucity of diagnostic tests demonstrating high sensitivity and specificity. Using two biomarkers, zinc-protoporphyrin/heme and hepcidin, we established the diagnostic cut-off values for iron deficiency anemia in preschool children and women. We randomly selected non-anemic individuals (n=190; women=90, children=100) and individuals with iron deficiency anemia (n=200; women=100, children=100) from a preexisting cohort of healthy prescho  ...[more]

Similar Datasets

| S-EPMC5532779 | biostudies-literature
| S-EPMC3669438 | biostudies-literature
| S-EPMC4439901 | biostudies-literature
2020-12-03 | GSE162493 | GEO
| S-EPMC9269377 | biostudies-literature
| S-EPMC8486982 | biostudies-literature
| S-EPMC2754723 | biostudies-literature
| S-EPMC4516762 | biostudies-literature
| S-EPMC3104019 | biostudies-literature
| S-EPMC7882357 | biostudies-literature