Changes in the Skin Conductance Monitor as an End Point for Sympathetic Nerve Blocks.


ABSTRACT: There is a lack of objective methods for determining the achievement of sympathetic block. This study validates the skin conductance monitor (SCM) as an end point indicator of successful sympathetic blockade as compared with traditional monitors.This interventional study included 13 patients undergoing 25 lumbar sympathetic blocks to compare time to indication of successful blockade between the SCM indices and traditional measures, clinically visible hyperemia, clinically visible engorgement of veins, subjective skin temperature difference, unilateral thermometry monitoring, bilateral comparative thermometry monitoring, and change in waveform amplitude in pulse oximetry plethysmography, within a 30-minute observation period. Differences in the SCM indices were studied pre- and postblock to validate the SCM.SCM showed substantially greater odds of indicating achievement of sympathetic block in the next moment (i.e., hazard rate) compared with all traditional measures (clinically visible hyperemia, clinically visible engorgement of veins, subjective temperature difference, unilateral thermometry monitoring, bilateral comparative thermometry monitoring, and change in waveform amplitude in pulse oximetry plethysmography; P???0.011). SCM indicated successful block for all (100%) procedures, while the traditional measures failed to indicate successful blocks in 16-84% of procedures. The SCM indices were significantly higher in preblock compared with postblock measurements (P?

SUBMITTER: Gungor S 

PROVIDER: S-EPMC6279270 | biostudies-literature | 2017 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Changes in the Skin Conductance Monitor as an End Point for Sympathetic Nerve Blocks.

Gungor Semih S   Rana Bhumika B   Fields Kara K   Bae James J JJ   Mount Lauren L   Buschiazzo Valeria V   Storm Hanne H  

Pain medicine (Malden, Mass.) 20171101 11


<h4>Objective</h4>There is a lack of objective methods for determining the achievement of sympathetic block. This study validates the skin conductance monitor (SCM) as an end point indicator of successful sympathetic blockade as compared with traditional monitors.<h4>Methods</h4>This interventional study included 13 patients undergoing 25 lumbar sympathetic blocks to compare time to indication of successful blockade between the SCM indices and traditional measures, clinically visible hyperemia,  ...[more]

Similar Datasets

| S-EPMC5753603 | biostudies-literature
| S-EPMC8620794 | biostudies-literature
| S-EPMC5182108 | biostudies-literature
| S-EPMC7606815 | biostudies-literature
| S-EPMC7331661 | biostudies-literature
| S-EPMC7117970 | biostudies-literature
| S-EPMC10771322 | biostudies-literature
| S-EPMC5712260 | biostudies-literature
| S-EPMC7673653 | biostudies-literature
| S-EPMC8669957 | biostudies-literature