Unknown

Dataset Information

0

Geometric and dosimetric evaluations of atlas-based segmentation methods of MR images in the head and neck region.


ABSTRACT: Owing to its excellent soft-tissue contrast, magnetic resonance (MR) imaging has found an increased application in radiation therapy (RT). By harnessing these properties for treatment planning, automated segmentation methods can alleviate the manual workload burden to the clinical workflow. We investigated atlas-based segmentation methods of organs at risk (OARs) in the head and neck (H&N) region using one approach that selected the most similar atlas from a library of segmented images and two multi-atlas approaches. The latter were based on weighted majority voting and an iterative atlas-fusion approach called STEPS. We built the atlas library from pre-treatment T1-weighted MR images of 12 patients with manual contours of the parotids, spinal cord and mandible, delineated by a clinician. Following a leave-one-out cross-validation strategy, we measured the geometric accuracy by calculating Dice similarity coefficients (DSC), standard and 95% Hausdorff distances (HD and HD95), and the mean surface distance (MSD), whereby the manual contours served as the gold standard. To benchmark the algorithm, we determined the inter-observer variability (IOV) between three observers. To investigate the dosimetric effect of segmentation inaccuracies, we implemented an auto-planning strategy within the treatment planning system Monaco (Elekta AB, Stockholm, Sweden). For each set of auto-segmented OARs, we generated a plan for a 9-beam step and shoot intensity modulated RT treatment, designed according to our institution's clinical H&N protocol. Superimposing the dose distributions on the gold standard OARs, we calculated dose differences to OARs caused by delineation differences between auto-segmented and gold standard OARs. We investigated the correlations between geometric and dosimetric differences. The mean DSC was larger than 0.8 and the mean MSD smaller than 2?mm for the multi-atlas approaches, resulting in a geometric accuracy comparable to previously published results and within the range of the IOV. While dosimetric differences could be as large as 23% of the clinical goal, treatment plans fulfilled all imposed clinical goals for the gold standard OARs. Correlations between geometric and dosimetric measures were low with R2??

SUBMITTER: Kieselmann JP 

PROVIDER: S-EPMC6296440 | biostudies-literature | 2018 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Geometric and dosimetric evaluations of atlas-based segmentation methods of MR images in the head and neck region.

Kieselmann J P JP   Kamerling C P CP   Burgos N N   Menten M J MJ   Fuller C D CD   Nill S S   Cardoso M J MJ   Oelfke U U  

Physics in medicine and biology 20180711 14


Owing to its excellent soft-tissue contrast, magnetic resonance (MR) imaging has found an increased application in radiation therapy (RT). By harnessing these properties for treatment planning, automated segmentation methods can alleviate the manual workload burden to the clinical workflow. We investigated atlas-based segmentation methods of organs at risk (OARs) in the head and neck (H&N) region using one approach that selected the most similar atlas from a library of segmented images and two m  ...[more]

Similar Datasets

| S-EPMC7042892 | biostudies-literature
| S-EPMC5540668 | biostudies-literature
| S-EPMC8357006 | biostudies-literature
| S-EPMC4469197 | biostudies-literature
| S-EPMC4474324 | biostudies-literature
| S-EPMC7784718 | biostudies-literature
| S-EPMC8657375 | biostudies-literature
| S-EPMC8048089 | biostudies-literature