Unknown

Dataset Information

0

Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure.


ABSTRACT: The objective of this study is to investigate the sensitivity of contrast-enhanced transthoracic echocardiography (c-TTE) versus transesophageal echocardiography (TEE) to detect a residual right-to-left shunt (RLS) following a transcatheter patent foramen ovale (PFO) closure.A self-controlled study was conducted in a tertiary referral hospital. 57 patients with PFO who had experienced migraines underwent percutaneous PFO closure. c-TTE, TEE, and contrast-enhanced transcranial Doppler (c-TCD) at resting and Valsalva maneuver were performed during the 3-month follow-up after the closure.The closure devices were successfully implanted in all patients without complications. Three months after closure, TEE did not detect residual Valsalva shunts in any of the 57 patients; residual valsalva shunts were found via c-TTE in 15 of the 57 patients and were also observed via c-TCD. When c-TTE and/or c-TCD were used, the rate of residual RLSs detected in patients who underwent PFO closure was 26.32%, which was significantly different than the rate detected using TEE (P?

SUBMITTER: Zhao H 

PROVIDER: S-EPMC6358410 | biostudies-literature | 2019 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure.

Zhao Hongling H   Yue Qingxiong Q   Wang Tao T   Wang Lin L   Pang Zhanqi Z   Dong He H   Yang Jian J   Li Yawen Y   Li Shijun S  

Medicine 20190101 4


The objective of this study is to investigate the sensitivity of contrast-enhanced transthoracic echocardiography (c-TTE) versus transesophageal echocardiography (TEE) to detect a residual right-to-left shunt (RLS) following a transcatheter patent foramen ovale (PFO) closure.A self-controlled study was conducted in a tertiary referral hospital. 57 patients with PFO who had experienced migraines underwent percutaneous PFO closure. c-TTE, TEE, and contrast-enhanced transcranial Doppler (c-TCD) at  ...[more]

Similar Datasets

| S-EPMC6532309 | biostudies-literature
| S-EPMC5699514 | biostudies-literature
| S-EPMC8815249 | biostudies-literature
| S-EPMC4170178 | biostudies-literature
| S-EPMC7726850 | biostudies-literature
| S-EPMC6275290 | biostudies-literature
| S-EPMC7501918 | biostudies-literature
| S-EPMC10021023 | biostudies-literature