An application of pacemaker respiratory monitoring system for the prediction of heart failure.


ABSTRACT: Sleep-disordered breathing (SDB) is one of the most common complications among heart failure (HF) patients. Changes of respiratory patterns during the various stages in patients with HF have not been fully investigated. In this case, the algorism using thoracic impedance sensor and minute ventilation (sleep apnea monitoring [SAM] algorithm) with implanted pacemaker (REPLY 200 SR or DR, Sorin CRM SAS, Clamart, France) was used to monitor respiration. Impedance data from the implanted pacemaker can be converted into respiratory data, which can be used to calculate the respiratory disturbance index (RDI) per unit of time. Using this algorithm, we observed a sudden appearance of abnormal breathing at the onset of HF, followed by gradual improvement of respiratory patterns during the recovery stage. The results from respiratory monitoring using the SAM algorithm were strongly correlated with those from the positive airway pressure device. This case report could imply that proper utilization of this sensor could facilitate the early detection and therapeutic control of HF.

SUBMITTER: Koyama T 

PROVIDER: S-EPMC6383190 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

An application of pacemaker respiratory monitoring system for the prediction of heart failure.

Koyama Takashi T   Kobayashi Masanori M   Ichikawa Tomohide T   Wakabayashi Tadamasa T   Abe Hidetoshi H  

Respiratory medicine case reports 20190216


Sleep-disordered breathing (SDB) is one of the most common complications among heart failure (HF) patients. Changes of respiratory patterns during the various stages in patients with HF have not been fully investigated. In this case, the algorism using thoracic impedance sensor and minute ventilation (sleep apnea monitoring [SAM] algorithm) with implanted pacemaker (REPLY 200 SR or DR, Sorin CRM SAS, Clamart, France) was used to monitor respiration. Impedance data from the implanted pacemaker ca  ...[more]

Similar Datasets

| S-EPMC3939720 | biostudies-literature
| S-EPMC9956019 | biostudies-literature
| S-EPMC4858435 | biostudies-literature
| S-EPMC9535791 | biostudies-literature
| S-EPMC6990820 | biostudies-literature
| S-EPMC3600881 | biostudies-other
| S-EPMC3254025 | biostudies-literature
| S-EPMC7835594 | biostudies-literature
| S-EPMC6661620 | biostudies-literature
| S-EPMC9773753 | biostudies-literature