Effect of heat-treatment on the pH sensitivity of stainless-steel electrodes as pH sensors.


ABSTRACT: Effect of heat-treatment on the pH sensitivity of uncoated stainless-steel electrodes was investigated to comprehend the pH sensitivity of metal-oxide coated stainless-steel electrodes as novel pH sensors. The pH sensitivity of stainless-steel electrodes as-received and heat-treated at 500 °C, 600 °C and 700 °C for 24 h were 91 %, 94 %, 102 % and 91 %, respectively. The pH sensitivity tended to increase with increasing heat-treatment time at a given temperature. Thus, the most suitable heat-treatment condition for the stainless-steel electrodes was 600 °C for 24 h. The austenite phase (fcc) was the main phase on the surface of the heat-treated stainless-steel electrodes. Unexpectedly, the change in the martensite phase (bcc) as the second phase with heat-treatment temperature was similar to the pH sensitivity, with the martensite phase affecting the pH sensitivity. Therefore, it appeared that the pH sensitivity of the metal-oxide coated stainless-steel electrodes was affected by the underlying stainless-steel as well as the outer metal-oxide film coating. A prototype stainless-steel tube electrode was used as a working electrode for demonstrating the depth profiling of pH. The stainless-steel tube electrode showed good performance for measuring pH depth profiles compared to commercially available glass electrodes.

SUBMITTER: Hashimoto T 

PROVIDER: S-EPMC6441752 | biostudies-literature | 2019 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Effect of heat-treatment on the pH sensitivity of stainless-steel electrodes as pH sensors.

Hashimoto Tadanori T   Kitabayashi Hiroki H   Ito Kenta K   Nasu Hiroyuki H   Ishihara Atsushi A   Nishio Yuji Y  

Heliyon 20190328 3


Effect of heat-treatment on the pH sensitivity of uncoated stainless-steel electrodes was investigated to comprehend the pH sensitivity of metal-oxide coated stainless-steel electrodes as novel pH sensors. The pH sensitivity of stainless-steel electrodes as-received and heat-treated at 500 °C, 600 °C and 700 °C for 24 h were 91 %, 94 %, 102 % and 91 %, respectively. The pH sensitivity tended to increase with increasing heat-treatment time at a given temperature. Thus, the most suitable heat-trea  ...[more]

Similar Datasets

| S-EPMC5377273 | biostudies-literature
| S-EPMC4761700 | biostudies-literature
| S-EPMC6646923 | biostudies-literature
| S-EPMC7424740 | biostudies-literature
2010-04-30 | GSE20174 | GEO
| S-EPMC7288148 | biostudies-literature
| S-EPMC6390200 | biostudies-literature
| S-EPMC7890476 | biostudies-literature
| S-EPMC5480826 | biostudies-literature
| S-EPMC5720180 | biostudies-literature