Unknown

Dataset Information

0

Identification of a Recombinant Human Interleukin-12 (rhIL-12) Fragment in Non-Reduced SDS-PAGE.


ABSTRACT: During the past two decades, recombinant human interleukin-12 (rhIL-12) has emerged as one of the most potent cytokines in mediating antitumor activity in a variety of preclinical models and clinical studies. Purity is a critical quality attribute (CQA) in the quality control system of rhIL-12. In our study, rhIL-12 bulks from manufacturer B showed a different pattern in non-reduced SDS-PAGE compared with size-exclusion chromatography (SEC)-HPLC. A small fragment was only detected in non-reduced SDS-PAGE but not in SEC-HPLC. The results of UPLC/MS and N-terminal sequencing confirmed that the small fragment was a 261?306 amino acid sequence of a p40 subunit of IL-12. The cleavage occurs between Lys260 and Arg261, a basic rich region. With the presence of 0.2% SDS, the small fragment appeared in both native PAGE and in SEC-HPLC, suggesting that it is bound to the remaining part of the IL-12 non-covalently, and is dissociated in a denatured environment. The results of a bioassay showed that the fractured rhIL-12 proteins had deficient biological activity. These findings provide an important reference for the quality control of the production process and the final products of rhIL-12.

SUBMITTER: Yu L 

PROVIDER: S-EPMC6479496 | biostudies-literature | 2019 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Identification of a Recombinant Human Interleukin-12 (rhIL-12) Fragment in Non-Reduced SDS-PAGE.

Yu Lei L   Li Yonghong Y   Tao Lei L   Jia Chuncui C   Yao Wenrong W   Rao Chunming C   Wang Junzhi J  

Molecules (Basel, Switzerland) 20190328 7


During the past two decades, recombinant human interleukin-12 (rhIL-12) has emerged as one of the most potent cytokines in mediating antitumor activity in a variety of preclinical models and clinical studies. Purity is a critical quality attribute (CQA) in the quality control system of rhIL-12. In our study, rhIL-12 bulks from manufacturer B showed a different pattern in non-reduced SDS-PAGE compared with size-exclusion chromatography (SEC)-HPLC. A small fragment was only detected in non-reduced  ...[more]

Similar Datasets

| S-EPMC5598364 | biostudies-literature
| S-EPMC5472695 | biostudies-literature
| S-EPMC6218646 | biostudies-literature
| S-EPMC1132587 | biostudies-other
| S-EPMC4913750 | biostudies-literature
| S-EPMC2644111 | biostudies-literature
| S-EPMC6992818 | biostudies-literature
| S-EPMC6152065 | biostudies-literature
| S-EPMC4887974 | biostudies-literature
| S-EPMC2077256 | biostudies-literature