Unknown

Dataset Information

0

Nylon mesh-based sample holder for fixed-target serial femtosecond crystallography.


ABSTRACT: Fixed-target serial femtosecond crystallography (FT-SFX) was an important advance in crystallography by dramatically reducing sample consumption, while maintaining the benefits of SFX for obtaining crystal structures at room temperature without radiation damage. Despite a number of advantages, preparation of a sample holder for the sample delivery in FT-SFX with the use of many crystals in a single mount at ambient temperature is challenging as it can be complicated and costly, and thus, development of an efficient sample holder is essential. In this study, we introduced a nylon mesh-based sample holder enclosed by a polyimide film. This sample holder can be rapidly manufactured using a commercially available nylon mesh with pores of a desired size at a low cost without challenging technology. Furthermore, this simple device is highly efficient in data acquisition. We performed FT-SFX using a nylon mesh-based sample holder and collected over 130,000 images on a single sample holder using a 30 Hz X-ray pulse for 1.2?h. We determined the crystal structures of lysozyme and glucose isomerase using the nylon mesh at 1.65 and 1.75?Å, respectively. The nylon mesh exposed to X-rays produced very low levels of background scattering at 3.75 and 4.30?Å, which are negligible for data analysis. Our method provides a simple and rapid but highly efficient way to deliver samples for FT-SFX.

SUBMITTER: Lee D 

PROVIDER: S-EPMC6502819 | biostudies-literature | 2019 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Nylon mesh-based sample holder for fixed-target serial femtosecond crystallography.

Lee Donghyeon D   Baek Sangwon S   Park Jaehyun J   Lee Keondo K   Kim Jangwoo J   Lee Sang Jae SJ   Chung Wan Kyun WK   Lee Jong-Lam JL   Cho Yunje Y   Nam Ki Hyun KH  

Scientific reports 20190506 1


Fixed-target serial femtosecond crystallography (FT-SFX) was an important advance in crystallography by dramatically reducing sample consumption, while maintaining the benefits of SFX for obtaining crystal structures at room temperature without radiation damage. Despite a number of advantages, preparation of a sample holder for the sample delivery in FT-SFX with the use of many crystals in a single mount at ambient temperature is challenging as it can be complicated and costly, and thus, develop  ...[more]

Similar Datasets

| S-EPMC6949605 | biostudies-literature
| S-EPMC8256716 | biostudies-literature
| S-EPMC4711646 | biostudies-literature
| S-EPMC7467159 | biostudies-literature
| S-EPMC8098472 | biostudies-literature
| S-EPMC5588887 | biostudies-literature
| S-EPMC5379936 | biostudies-literature
| S-EPMC6400179 | biostudies-literature
| S-EPMC4711622 | biostudies-literature