Unknown

Dataset Information

0

Antidepressant outcomes of high-frequency repetitive transcranial magnetic stimulation (rTMS) with F8-coil and deep transcranial magnetic stimulation (DTMS) with H1-coil in major depression: a systematic review and meta-analysis.


ABSTRACT: BACKGROUND:The current study aims to systematically assess and compare the antidepressant outcomes of repetitive transcranial magnetic stimulation (rTMS) with the figure-of-eight (F8)-coil and deep transcranial magnetic stimulation (DTMS) with the H1-coil in studies matched on stimulation frequency in unipolar major depressive disorder (MDD). METHODS:Electronic search of Medline and PsycInfo identified 19 studies with stimulation frequency of 18-20?Hz using F8-coil (k?=?8 randomised sham-controlled trials, RCTs, k?=?3 open-label; n?=?168 patients) or H1-coil (k?=?1 RCT, k?=?7 open-label; n?=?200). Depression severity (the primary outcome) and response/remission rates (the secondary outcomes) were assessed at session 10. RESULTS:Effects pooled with random-effects meta-analysis showed a large reduction in depression severity, 29% response, and 15% remission rates after 10 sessions of active stimulation with either coil relative to baseline. Reduction in depression severity was greater in studies with younger patients using either coil. The comparison between coils showed a larger reduction in depression severity in H1-coil vs. F8-coil studies (independent of the study design or the concurrent pharmacotherapy) and a trend towards higher remission rates in F8-coil vs. H1-coils studies. These effects are based on a low volume of studies, are not controlled for placebo, and may not be clinically-relevant. The stimulation protocols differed systematically because stimulation was more focal but less intense (80-110% of the resting motor threshold, MT) in the F8-coil studies and less focal but more intense (120% MT) in the H1-coil studies. Two seizures occurred in the H1-coil studies relative to none in the F8-coil studies. CONCLUSION:When matched on frequency, the higher-intensity and less focal stimulation with the H1-coil reduces depression more than the lower-intensity and more focal stimulation with the F8-coil. Head-to-head trials should compare the antidepressant outcomes of F8-coil and H1-coil to identify the most optimal stimulation protocols for acute and longer-lasting efficacy.

SUBMITTER: Gellersen HM 

PROVIDER: S-EPMC6505129 | biostudies-literature | 2019 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Antidepressant outcomes of high-frequency repetitive transcranial magnetic stimulation (rTMS) with F8-coil and deep transcranial magnetic stimulation (DTMS) with H1-coil in major depression: a systematic review and meta-analysis.

Gellersen Helena M HM   Kedzior Karina Karolina KK  

BMC psychiatry 20190507 1


<h4>Background</h4>The current study aims to systematically assess and compare the antidepressant outcomes of repetitive transcranial magnetic stimulation (rTMS) with the figure-of-eight (F8)-coil and deep transcranial magnetic stimulation (DTMS) with the H1-coil in studies matched on stimulation frequency in unipolar major depressive disorder (MDD).<h4>Methods</h4>Electronic search of Medline and PsycInfo identified 19 studies with stimulation frequency of 18-20 Hz using F8-coil (k = 8 randomis  ...[more]

Similar Datasets

2023-05-30 | GSE230150 | GEO
| S-EPMC6885044 | biostudies-literature
2023-05-30 | GSE230149 | GEO
2023-05-30 | GSE230147 | GEO
2023-05-30 | GSE230148 | GEO
2022-08-10 | GSE192910 | GEO