Unknown

Dataset Information

0

Spatiotemporal Complexity of the Aortic Sinus Vortex as a Function of Leaflet Calcification.


ABSTRACT: Several studies have shown the variation of aortic sinus structures' hemodynamics with different flow and geometric characteristics. They have also correlated aortic sinus hemodynamics with the progression and evolution of calcific aortic valve disease (CAVD). This study aims at visualizing aortic sinus fluid structure variations as functions of different leaflet calcification degrees and assessing their potential relationship with CAVD. A degenerated 23 mm Carpentier-Edwards Perimount Magna valve extracted from a redo-surgery patient was implanted in an aortic root model and tested in a pulse duplicator left heart simulator. The valve has 3 leaflets with 3 different levels of calcium distribution: mild, moderate and severe. High-speed imaging and particle image velocimetry were performed to assess sinus vortices, leaflet tip position and velocity along with shear stress. Results have shown that (a) aortic sinus vortices initiation, entrapment and evolution varied with different calcified leaflet exposure; (b) higher velocities in the sinus were calculated with the mildly calcified leaflet compared to the moderately and severely calcified ones; (c) during systole, the mildly calcified leaflet sinus case shows the most spread-out and higher ranges of shear stress probabilities and highest magnitudes going from (-?1.5 to +?1.8 Pa) compared with (-?1.0 to +?1.0 Pa) for moderately and severely calcified leaflets. The higher the calcification degree the lower the shear stress range and likelihoods of having higher shear stress. This holds in diastole as well. This study shows the impact of calcification on the aortic sinus flow structures.

SUBMITTER: Hatoum H 

PROVIDER: S-EPMC6525337 | biostudies-literature | 2019 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Spatiotemporal Complexity of the Aortic Sinus Vortex as a Function of Leaflet Calcification.

Hatoum Hoda H   Dasi Lakshmi Prasad LP  

Annals of biomedical engineering 20190201 4


Several studies have shown the variation of aortic sinus structures' hemodynamics with different flow and geometric characteristics. They have also correlated aortic sinus hemodynamics with the progression and evolution of calcific aortic valve disease (CAVD). This study aims at visualizing aortic sinus fluid structure variations as functions of different leaflet calcification degrees and assessing their potential relationship with CAVD. A degenerated 23 mm Carpentier-Edwards Perimount Magna val  ...[more]

Similar Datasets

| S-EPMC4106046 | biostudies-literature
| S-EPMC4838673 | biostudies-literature
| S-EPMC6613808 | biostudies-literature
| S-EPMC10914776 | biostudies-literature
| S-EPMC5586405 | biostudies-literature
| S-EPMC3675204 | biostudies-literature
| S-EPMC3861133 | biostudies-literature
| S-EPMC8638812 | biostudies-literature
| S-EPMC6597454 | biostudies-literature
| S-EPMC5216198 | biostudies-literature