Unknown

Dataset Information

0

Concordance of the point-of-care circulating cathodic antigen test for the diagnosis of intestinal schistosomiasis in a low endemicity area.


ABSTRACT: BACKGROUND:The Kato-Katz technique is recommended worldwide for the diagnosis of intestinal schistosomiasis, detecting parasite eggs in feces of infected people. However, new tests have been developed in order to facilitate diagnosis, e.g. by detection of specific antigens secreted by schistosomes, such as the circulating cathodic antigen (CCA). The aim of this study was to evaluate the performance of the point-of-care circulating cathodic antigen test (POC-CCA) compared to the Kato-Katz technique in a low prevalence area in the Amazon Region, located in the municipality of Primavera, State of Pará, Brazil. METHODS:Positivity rates of the POC-CCA test and the Kato-Katz technique were calculated. The sensitivity, specificity, accuracy and kappa coefficient were determined by comparing both methods. The reference standard was established using 16 Kato-Katz slides, 12 of the first fecal sample, two of the second and two of the third one. The study also included the concordance between POC-CCA results and different numbers and combinations of Kato-Katz slides. RESULTS:The prevalence of schistosomiasis according to the reference standard or POC-CCA test reached a rate of 9.4% or 23.9%, respectively, among a total of 372 participants. The positivity rates by the Kato-Katz technique increased from 2.4 to 9.4%, according to the increase in the number of slides examined and fecal samples collected. A sensitivity of 55.6%, specificity 76.9%, accuracy 76% and ? coefficient of 0.06 was observed by comparing one slide of the first sample and POC-CCA. Comparing 6 slides from three different samples, two slides of each, with POC-CCA resulted in a sensitivity of 58.3%, specificity 78.4%, accuracy 77% and ? coefficient of 0.16. Finally, the comparison of 16 slides from three different samples with POC-CCA revealed a sensitivity of 65.7%, specificity 80.4%, accuracy 79%, and ? coefficient of 0.27. CONCLUSIONS:The immunochromatographic test has the potential to be an important tool to combat schistosomiasis because of its practicality and applicability but should be applied with caution in low prevalence areas and in programs that aim to eliminate this disease. TRIAL REGISTRATION:CAAE#21824513.9.0000.5091 . January 31st, 2014.

SUBMITTER: de Sousa SRM 

PROVIDER: S-EPMC6542115 | biostudies-literature | 2019 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Concordance of the point-of-care circulating cathodic antigen test for the diagnosis of intestinal schistosomiasis in a low endemicity area.

de Sousa Sergei Rodrigo Magalhães SRM   Dias Isabelle Helena Lima IHL   Fonseca Álvaro Luan Santana ÁLS   Contente Bianca Rodrigues BR   Nogueira Joyce Favacho Cardoso JFC   da Costa Oliveira Tatyellen Natasha TN   Geiger Stefan Michael SM   Enk Martin Johannes MJ  

Infectious diseases of poverty 20190530 1


<h4>Background</h4>The Kato-Katz technique is recommended worldwide for the diagnosis of intestinal schistosomiasis, detecting parasite eggs in feces of infected people. However, new tests have been developed in order to facilitate diagnosis, e.g. by detection of specific antigens secreted by schistosomes, such as the circulating cathodic antigen (CCA). The aim of this study was to evaluate the performance of the point-of-care circulating cathodic antigen test (POC-CCA) compared to the Kato-Katz  ...[more]

Similar Datasets

| S-EPMC3554525 | biostudies-literature
| S-EPMC5552248 | biostudies-other
| S-EPMC6310297 | biostudies-literature
| S-EPMC6786642 | biostudies-literature
| S-EPMC3222626 | biostudies-literature
| S-EPMC3868541 | biostudies-literature
| S-EPMC7356434 | biostudies-literature
| S-EPMC3605147 | biostudies-literature
| S-EPMC5361543 | biostudies-literature
| S-EPMC7360052 | biostudies-literature