Ultrasensitive detection of circulating exosomes with a 3D-nanopatterned microfluidic chip.


ABSTRACT: The performance of current microfluidic methods for exosome detection is constrained by boundary conditions, as well as fundamental limits to microscale mass transfer and interfacial exosome binding. Here, we show that a microfluidic chip designed with self-assembled three-dimensional herringbone nanopatterns can detect low levels of tumour-associated exosomes in plasma (10?exosomes??l-1, or approximately 200 vesicles per 20??l of spiked sample) that would otherwise be undetectable by standard microfluidic systems for biosensing. The nanopatterns promote microscale mass transfer, increase surface area and probe density to enhance the efficiency and speed of exosome binding, and permit drainage of the boundary fluid to reduce near-surface hydrodynamic resistance, thus promoting particle-surface interactions for exosome binding. We used the device for the detection-in 2??l plasma samples from 20 ovarian cancer patients and 10 age-matched controls-of exosome subpopulations expressing CD24, epithelial cell adhesion molecule and folate receptor alpha proteins, and suggest exosomal folate receptor alpha as a potential biomarker for early detection and progression monitoring of ovarian cancer. The nanolithography-free nanopatterned device should facilitate the use of liquid biopsies for cancer diagnosis.

SUBMITTER: Zhang P 

PROVIDER: S-EPMC6556143 | biostudies-literature | 2019 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ultrasensitive detection of circulating exosomes with a 3D-nanopatterned microfluidic chip.

Zhang Peng P   Zhou Xin X   He Mei M   Shang Yuqin Y   Tetlow Ashley L AL   Godwin Andrew K AK   Zeng Yong Y  

Nature biomedical engineering 20190225 6


The performance of current microfluidic methods for exosome detection is constrained by boundary conditions, as well as fundamental limits to microscale mass transfer and interfacial exosome binding. Here, we show that a microfluidic chip designed with self-assembled three-dimensional herringbone nanopatterns can detect low levels of tumour-associated exosomes in plasma (10 exosomes μl<sup>-1</sup>, or approximately 200 vesicles per 20 μl of spiked sample) that would otherwise be undetectable by  ...[more]

Similar Datasets

| S-EPMC4970962 | biostudies-literature
| S-EPMC4134440 | biostudies-literature
| S-EPMC6934608 | biostudies-literature
| S-EPMC6567039 | biostudies-literature
| S-EPMC5811381 | biostudies-literature
| S-EPMC4726319 | biostudies-literature
| S-EPMC6504191 | biostudies-literature
| S-EPMC11230801 | biostudies-literature
| S-EPMC4303339 | biostudies-literature
| S-EPMC5378374 | biostudies-literature