Reagent strips test: A simplified method for prompt analysis of cerebrospinal fluid in neurological disorders in emergency.


ABSTRACT:

Introduction

The initial examination of cerebrospinal fluid (CSF) for proteins, glucose, and leukocytes, is still the gold standard investigation in some neurological conditions like meningitis. Aims and objective of the present study were to determine the accuracy of urinary reagent strip for semi-quantitative analysis of protein, glucose, leucocytes and erythrocytes in CSF along with its role in emergency for rapid diagnosis of neurological conditions.

Materials and methods

360 samples of CSF were received in emergency laboratory of a tertiary care hospital in a period of 6 months. All CSF samples were subjected to two types of tests-the definitive test and the index test. CSF microscopy for leucocyte and erythrocyte as well as biochemistry tests for protein and glucose on automated biochemistry analyser were considered as definitive test. The index test for protein, glucose, leucocyte and erythrocyte for the same sample was conducted by Combur-10 urinary reagent strip.

Result

The strip test showed a sensitivity of 99% and a specificity of 54% for proteins. With respect to glucose, the strip was highly sensitive (98%) as well as highly specific (92%).It showed a high sensitivity and specificity for leukocytes???10?cells/cumm i.e.100% and 96% respectively. For CSF erythrocytes sensitivity and specificity was 100.

Conclusion

Urinary reagent strip can be used routinely for rapid analysis of CSF. If implemented, this technique will be useful especially in emergency settings as well as in areas with limited resources.

SUBMITTER: Gupta A 

PROVIDER: S-EPMC6562142 | biostudies-literature | 2019 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reagent strips test: A simplified method for prompt analysis of cerebrospinal fluid in neurological disorders in emergency.

Gupta Anshu A   Dwivedi Tanima T  

Practical laboratory medicine 20190521


<h4>Introduction</h4>The initial examination of cerebrospinal fluid (CSF) for proteins, glucose, and leukocytes, is still the gold standard investigation in some neurological conditions like meningitis. Aims and objective of the present study were to determine the accuracy of urinary reagent strip for semi-quantitative analysis of protein, glucose, leucocytes and erythrocytes in CSF along with its role in emergency for rapid diagnosis of neurological conditions.<h4>Materials and methods</h4>360  ...[more]

Similar Datasets

| S-EPMC7998212 | biostudies-literature
| S-EPMC8044304 | biostudies-literature
2020-12-11 | GSE163005 | GEO
| S-EPMC7022863 | biostudies-literature
| S-EPMC3549487 | biostudies-literature
| S-EPMC10795297 | biostudies-literature
| S-EPMC7417278 | biostudies-literature
| S-EPMC7718900 | biostudies-literature
| S-EPMC6742728 | biostudies-literature
| S-EPMC5526718 | biostudies-literature