Unknown

Dataset Information

0

Energy storage: pseudocapacitance in prospect.


ABSTRACT: The two main types of charge storage devices - batteries and double layer charging capacitors - can be unambiguously distinguished from one another by the shape and scan rate dependence of their cyclic voltammetric current-potential (CV) responses. This is not the case with "pseudocapacitors" and with the notion of "pseudocapacitance", as originally put forward by Conway et al. After insisting on the necessity of precisely defining "pseudocapacitance" as involving faradaic processes and having, at the same time, a capacitive signature, we discuss the modelling of "pseudocapacitive" responses, revisiting Conway's derivations and analysing critically the other contributions to the subject, leading unmistakably to the conclusion that "pseudocapacitors" are actually true capacitors and that "pseudocapacitance" is a basically incorrect notion. Taking cobalt oxide films as a tutorial example, we describe the way in which a (true) electrical double layer is built upon oxidation of the film in its insulating state up to an ohmic conducting state. The lessons drawn at this occasion are used to re-examine the classical oxides, RuO2, MnO2, TiO2, Nb2O5 and other examples of putative "pseudocapacitive" materials. Addressing the dynamics of charge storage-a key issue in the practice of power of the energy storage device-it is shown that ohmic potential drop in the pores is the governing factor rather than counter-ion diffusion as often asserted, based on incorrect diagnosis by means of scan rate variations in CV studies.

SUBMITTER: Costentin C 

PROVIDER: S-EPMC6563784 | biostudies-literature | 2019 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Energy storage: pseudocapacitance in prospect.

Costentin Cyrille C   Savéant Jean-Michel JM  

Chemical science 20190509 22


The two main types of charge storage devices - batteries and double layer charging capacitors - can be unambiguously distinguished from one another by the shape and scan rate dependence of their cyclic voltammetric current-potential (CV) responses. This is not the case with "pseudocapacitors" and with the notion of "pseudocapacitance", as originally put forward by Conway <i>et al.</i> After insisting on the necessity of precisely defining "pseudocapacitance" as involving faradaic processes and h  ...[more]

Similar Datasets

| S-EPMC4931321 | biostudies-literature
| S-EPMC9737611 | biostudies-literature
| S-EPMC5956078 | biostudies-literature
| S-EPMC8111675 | biostudies-literature
| S-EPMC7770734 | biostudies-literature
| S-EPMC8187546 | biostudies-literature
| S-EPMC9348786 | biostudies-literature
| S-EPMC5114596 | biostudies-literature
| S-EPMC11297214 | biostudies-literature
| S-EPMC8991206 | biostudies-literature