Measuring clinically relevant knee motion with a self-calibrated wearable sensor.


ABSTRACT: Low-cost sensors provide a unique opportunity to continuously monitor patient progress during rehabilitation; however, these sensors have yet to demonstrate the fidelity and lack the calibration paradigms necessary to be viable tools for clinical research. The purpose of this study was to validate a low-cost wearable sensor that accurately measured peak knee extension during clinical exercises and needed no additional equipment for calibration. Sagittal plane knee motion was quantified using a 9-axis motion sensor and directly compared to motion capture data. The motion sensor measured the field strength of a strong earth magnet secured to the distal femur, which was correlated with knee angle during a simple calibration process. Peak knee motions and kinematic patterns were compared with motion capture data using paired t-tests and cross correlation, respectively. Peak extension values during seated knee extensions were accurate within 5 degrees across all subjects (root mean square error: 2.6 degrees, P?=?0.29). Knee flexion during gait strongly correlated (0.84???rxy???0.99) with motion capture measurements but demonstrated peak flexion errors of 10 degrees. In this study, we present a low-cost sensor (?$?35?US) that accurately determines knee extension angle following a calibration procedure that did not require any other equipment. Our findings demonstrate that this sensor paradigm is a feasible tool to monitor patient progress throughout physical therapy. However, dynamic motions that are associated with soft-tissue artifact may limit the accuracy of this type of wearable sensor.

SUBMITTER: Hullfish TJ 

PROVIDER: S-EPMC6587970 | biostudies-literature | 2019 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Measuring clinically relevant knee motion with a self-calibrated wearable sensor.

Hullfish Todd J TJ   Qu Feini F   Stoeckl Brendan D BD   Gebhard Peter M PM   Mauck Robert L RL   Baxter Josh R JR  

Journal of biomechanics 20190405


Low-cost sensors provide a unique opportunity to continuously monitor patient progress during rehabilitation; however, these sensors have yet to demonstrate the fidelity and lack the calibration paradigms necessary to be viable tools for clinical research. The purpose of this study was to validate a low-cost wearable sensor that accurately measured peak knee extension during clinical exercises and needed no additional equipment for calibration. Sagittal plane knee motion was quantified using a 9  ...[more]

Similar Datasets

| S-EPMC7015375 | biostudies-literature
| S-EPMC7351784 | biostudies-literature
| S-EPMC6891807 | biostudies-literature
| S-EPMC10211429 | biostudies-literature
| S-EPMC7527225 | biostudies-literature
| S-EPMC4557336 | biostudies-literature
| S-EPMC9978046 | biostudies-literature
| S-EPMC9677178 | biostudies-literature
| S-EPMC10857196 | biostudies-literature
| S-EPMC7251314 | biostudies-literature