Air quality and presence of air ventilation systems inside waterpipe cafes in North Carolina.
Ontology highlight
ABSTRACT: BACKGROUND:After North Carolina (NC) fire inspectors detected unsafe carbon monoxide (CO) levels inside several waterpipe cafés, the state fire code was amended to include provisions regulating waterpipe cafés, adding a requirement for air ventilation. These regulations apply to new buildings constructed after 1 January 2016, but can be enforced for older buildings where there exists a distinct hazard to life. We measured air quality at a sample of waterpipe cafés before and after the starting date of this regulation and collected information on presence of air ventilation. METHODS:Air quality (CO, fine particulate matter (PM2.5)) monitoring was conducted inside and outside of six waterpipe cafés in NC in September of 2015 (time 1) and September of 2016 (time 2). In addition, questionnaires were administered to managers from each waterpipe café at time 2 to determine the presence of air ventilation systems. RESULTS:Elevated levels of CO and PM2.5 were found inside waterpipe cafés at time 1 (median CO=42?ppm; median PM2.5=379.3?µg/m3) and time 2 (median CO=65?ppm; median PM2.5=484.0?µg/m3), with no significant differences between time periods (p>0.05). Indoor levels were significantly higher than levels outside cafés at both time periods (p<0.05). All waterpipe cafés reported having an air ventilation system that was installed prior to time 1 air monitoring. CONCLUSIONS:Unsafe levels of CO and PM2.5 were observed in waterpipe cafés in NC, despite reported use of air ventilation systems. Prohibiting indoor waterpipe smoking may be necessary to ensure clean air for employees and patrons.
SUBMITTER: Seidenberg AB
PROVIDER: S-EPMC6590895 | biostudies-literature | 2019 May
REPOSITORIES: biostudies-literature
ACCESS DATA