Unknown

Dataset Information

0

Low-dose X-ray structure analysis of cytochrome c oxidase utilizing high-energy X-rays.


ABSTRACT: To investigate the effect of high-energy X-rays on site-specific radiation-damage, low-dose diffraction data were collected from radiation-sensitive crystals of the metal enzyme cytochrome c oxidase. Data were collected at the Structural Biology I beamline (BL41XU) at SPring-8, using 30?keV X-rays and a highly sensitive pixel array detector equipped with a cadmium telluride sensor. The experimental setup of continuous sample translation using multiple crystals allowed the average diffraction weighted dose per data set to be reduced to 58?kGy, and the resulting data revealed a ligand structure featuring an identical bond length to that in the damage-free structure determined using an X-ray free-electron laser. However, precise analysis of the residual density around the ligand structure refined with the synchrotron data showed the possibility of a small level of specific damage, which might have resulted from the accumulated dose of 58?kGy per data set. Further investigation of the photon-energy dependence of specific damage, as assessed by variations in UV-vis absorption spectra, was conducted using an on-line spectrometer at various energies ranging from 10 to 30?keV. No evidence was found for specific radiation damage being energy dependent.

SUBMITTER: Ueno G 

PROVIDER: S-EPMC6613116 | biostudies-literature | 2019 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Low-dose X-ray structure analysis of cytochrome c oxidase utilizing high-energy X-rays.

Ueno Go G   Shimada Atsuhiro A   Yamashita Eiki E   Hasegawa Kazuya K   Kumasaka Takashi T   Shinzawa-Itoh Kyoko K   Yoshikawa Shinya S   Tsukihara Tomitake T   Yamamoto Masaki M  

Journal of synchrotron radiation 20190614 Pt 4


To investigate the effect of high-energy X-rays on site-specific radiation-damage, low-dose diffraction data were collected from radiation-sensitive crystals of the metal enzyme cytochrome c oxidase. Data were collected at the Structural Biology I beamline (BL41XU) at SPring-8, using 30 keV X-rays and a highly sensitive pixel array detector equipped with a cadmium telluride sensor. The experimental setup of continuous sample translation using multiple crystals allowed the average diffraction wei  ...[more]

Similar Datasets

| S-EPMC2833029 | biostudies-literature
| S-EPMC6203177 | biostudies-literature
2020-10-07 | GSE159080 | GEO
2013-07-26 | GSE47782 | GEO
| S-EPMC5544322 | biostudies-literature
| S-EPMC3925067 | biostudies-literature
2013-07-26 | E-GEOD-47782 | biostudies-arrayexpress
| S-EPMC3387041 | biostudies-literature
| S-EPMC6330080 | biostudies-literature
| S-EPMC6971206 | biostudies-literature