Real-time local oxygen measurements for high resolution cellular imaging.


ABSTRACT: Single-cell metabolic investigations are hampered by the absence of flexible tools to measure local partial pressure of O2 (pO2) at high spatial-temporal resolution. To this end, we developed an optical sensor capable of measuring local pericellular pO2 for subcellular resolution measurements with confocal imaging while simultaneously carrying out electrophysiological and/or chemo-mechanical single cell experiments. Here we present the OxySplot optrode, a ratiometric fluorescent O2-micro-sensor created by adsorbing O2-sensitive and O2-insensitive fluorophores onto micro-particles of silica. To protect the OxySplot optrode from the components and reactants of liquid environment without compromising access to O2, the micro-particles are coated with an optically clear silicone polymer (PDMS, polydimethylsiloxane). The PDMS coated OxySplot micro-particles are used alone or in a thin (~50??m) PDMS layer of arbitrary shape referred to as the OxyMat. Additional top coatings on the OxyMat (e.g., fibronectin, laminin, polylysine, special photoactivatable surfaces etc.) facilitate adherence of cells. The OxySplots report the cellular pO2 and micro-gradients of pO2 without disrupting the flow of extracellular solutions or interfering with patch-clamp pipettes, mechanical attachments, and micro-superfusion. Since OxySplots and a cell can be imaged and spatially resolved, calibrated changes of pO2 and intracellular events can be imaged simultaneously. In addition, the response-time (t0.5?=?0.7?s, 0-160?mmHg) of OxySplots is ~100 times faster than amperometric Clark-type polarization microelectrodes. Two usage example of OxySplots with cardiomyocytes show (1) OxySplots measuring pericellular pO2 while tetramethylrhodamine methyl-ester (TMRM) was used to measure mitochondrial membrane potential (??m); and (2) OxySplots measuring pO2 during ischemia and reperfusion while rhod-2 was used to measure cytosolic [Ca2+]i levels simultaneously. The OxySplot/OxyMat optrode system provides an affordable and highly adaptable optical sensor system for monitoring pO2 with a diverse array of imaging systems, including high-speed, high-resolution confocal microscopes while physiological features are measured simultaneously.

SUBMITTER: Boyman L 

PROVIDER: S-EPMC6613206 | biostudies-literature | 2019 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Real-time local oxygen measurements for high resolution cellular imaging.

Boyman Liron L   Williams George S B GSB   Wescott Andrew P AP   Leach Jennie B JB   Kao Joseph P Y JPY   Lederer W Jonathan WJ  

Journal of molecular and cellular cardiology 20181205


Single-cell metabolic investigations are hampered by the absence of flexible tools to measure local partial pressure of O<sub>2</sub> (pO<sub>2</sub>) at high spatial-temporal resolution. To this end, we developed an optical sensor capable of measuring local pericellular pO<sub>2</sub> for subcellular resolution measurements with confocal imaging while simultaneously carrying out electrophysiological and/or chemo-mechanical single cell experiments. Here we present the OxySplot optrode, a ratiome  ...[more]

Similar Datasets

| S-EPMC4794724 | biostudies-literature
| S-EPMC9640670 | biostudies-literature
| S-EPMC6486671 | biostudies-literature
| S-EPMC4595625 | biostudies-literature
| S-EPMC3469983 | biostudies-other
| S-EPMC8196160 | biostudies-literature
| S-EPMC4025902 | biostudies-other
| S-EPMC6342823 | biostudies-literature
| S-EPMC8637545 | biostudies-literature
| S-EPMC4186763 | biostudies-literature