Unknown

Dataset Information

0

Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis.


ABSTRACT: Endovascular repair has become the standard of care for treatment of abdominal aortic aneurysms. The endografts and delivery systems for endovascular aneurysm repair have undergone multiple generations of technologic advancements. However, a significant remaining challenge for a satisfactory long-term outcome is to improve the performance of these devices in nonideal proximal sealing zones. In particular, short (<15 mm) and highly angulated (>60 degrees) necks can threaten long-term exclusion of the aneurysm even with the current generation of endografts. One of the main reasons for proximal infrarenal neck failure is the inability to accurately position the endograft precisely below both renal arteries. This is a report of the first-in-human implantations of the GORE EXCLUDER Conformable AAA Endoprosthesis (W. L. Gore & Associates, Flagstaff, Ariz), an investigational device, in anatomies with standard neck lengths and angulation. This device has been designed to provide repositionability, conformability, and, for the first time, optional angulation control. This device is commercially available in Europe.

SUBMITTER: Rhee R 

PROVIDER: S-EPMC6614708 | biostudies-literature | 2019 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis.

Rhee Robert R   Peterson Brian B   Moore Erin E   Lepore Michael M   Oderich Gustavo G  

Journal of vascular surgery cases and innovative techniques 20190629 3


Endovascular repair has become the standard of care for treatment of abdominal aortic aneurysms. The endografts and delivery systems for endovascular aneurysm repair have undergone multiple generations of technologic advancements. However, a significant remaining challenge for a satisfactory long-term outcome is to improve the performance of these devices in nonideal proximal sealing zones. In particular, short (<15 mm) and highly angulated (>60 degrees) necks can threaten long-term exclusion of  ...[more]

Similar Datasets

| S-EPMC10641676 | biostudies-literature
| S-EPMC7115704 | biostudies-literature
| S-EPMC11323428 | biostudies-literature
| S-EPMC7414792 | biostudies-literature
| S-EPMC5495780 | biostudies-literature
| S-EPMC6635094 | biostudies-literature
| S-EPMC10248942 | biostudies-literature
| S-EPMC5352493 | biostudies-literature
| S-EPMC4105161 | biostudies-literature
| S-EPMC10054495 | biostudies-literature