Unknown

Dataset Information

0

FLAIR2 improves LesionTOADS automatic segmentation of multiple sclerosis lesions in non-homogenized, multi-center, 2D clinical magnetic resonance images.


ABSTRACT: BACKGROUND:Accurate segmentation of MS lesions on MRI is difficult and, if performed manually, time consuming. Automatic segmentations rely strongly on the image contrast and signal-to-noise ratio. Literature examining segmentation tool performances in real-world multi-site data acquisition settings is scarce. OBJECTIVE:FLAIR2, a combination of T2-weighted and fluid attenuated inversion recovery (FLAIR) images, improves tissue contrast while suppressing CSF. We compared the use of FLAIR and FLAIR2 in LesionTOADS, OASIS and the lesion segmentation toolbox (LST) when applied to non-homogenized, multi-center 2D-imaging data. METHODS:Lesions were segmented on 47 MS patient data sets obtained from 34 sites using LesionTOADS, OASIS and LST, and compared to a semi-automatically generated reference. The performance of FLAIR and FLAIR2 was assessed using the relative lesion volume difference (LVD), Dice coefficient (DSC), sensitivity (SEN) and symmetric surface distance (SSD). Performance improvements related to lesion volumes (LVs) were evaluated for all tools. For comparison, LesionTOADS was also used to segment lesions from 3?T single-center MR data of 40 clinically isolated syndrome (CIS) patients. RESULTS:Compared to FLAIR, the use of FLAIR2 in LesionTOADS led to improvements of 31.6% (LVD), 14.0% (DSC), 25.1% (SEN), and 47.0% (SSD) in the multi-center study. DSC and SSD significantly improved for larger LVs, while LVD and SEN were enhanced independent of LV. OASIS showed little difference between FLAIR and FLAIR2, likely due to its inherent use of T2w and FLAIR. LST replicated the benefits of FLAIR2 only in part, indicating that further optimization, particularly at low LVs is needed. In the CIS study, LesionTOADS did not benefit from the use of FLAIR2 as the segmentation performance for both FLAIR and FLAIR2 was heterogeneous. CONCLUSIONS:In this real-world, multi-center experiment, FLAIR2 outperformed FLAIR in its ability to segment MS lesions with LesionTOADS. The computation of FLAIR2 enhanced lesion detection, at minimally increased computational time or cost, even retrospectively. Further work is needed to determine how LesionTOADS and other tools, such as LST, can optimally benefit from the improved FLAIR2 contrast.

SUBMITTER: Le M 

PROVIDER: S-EPMC6646743 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

FLAIR<sup>2</sup> improves LesionTOADS automatic segmentation of multiple sclerosis lesions in non-homogenized, multi-center, 2D clinical magnetic resonance images.

Le M M   Tang L Y W LYW   Hernández-Torres E E   Jarrett M M   Brosch T T   Metz L L   Li D K B DKB   Traboulsee A A   Tam R C RC   Rauscher A A   Wiggermann V V  

NeuroImage. Clinical 20190705


<h4>Background</h4>Accurate segmentation of MS lesions on MRI is difficult and, if performed manually, time consuming. Automatic segmentations rely strongly on the image contrast and signal-to-noise ratio. Literature examining segmentation tool performances in real-world multi-site data acquisition settings is scarce.<h4>Objective</h4>FLAIR<sup>2</sup>, a combination of T<sub>2</sub>-weighted and fluid attenuated inversion recovery (FLAIR) images, improves tissue contrast while suppressing CSF.  ...[more]

Similar Datasets

| S-EPMC4474324 | biostudies-literature
| S-EPMC2830007 | biostudies-literature
| S-EPMC10043498 | biostudies-literature
| S-EPMC7849889 | biostudies-literature
| S-EPMC5430150 | biostudies-literature
| S-EPMC10242366 | biostudies-literature
| S-EPMC7459118 | biostudies-literature
| S-EPMC6759925 | biostudies-literature
| S-EPMC8409666 | biostudies-literature
| S-EPMC8864013 | biostudies-literature