An active learning framework for enhancing identification of non-artifactual intracranial pressure waveforms.


ABSTRACT: OBJECTIVE:Intracranial pressure (ICP) is an important and established clinical measurement that is used in the management of severe acute brain injury. ICP waveforms are usually triphasic and are susceptible to artifact because of transient catheter malfunction or routine patient care. Existing methods for artifact detection include threshold-based, stability-based, or template matching, and result in higher false positives (when there is variability in the ICP waveforms) or higher false negatives (when the ICP waveforms lack complete triphasic components but are valid). APPROACH:We hypothesized that artifact labeling of ICP waveforms can be optimized by an active learning approach which includes interactive querying of domain experts to identify a manageable number of informative training examples. MAIN RESULTS:The resulting active learning based framework identified non-artifactual ICP pulses with a superior AUC of 0.96 + 0.012, compared to existing methods: template matching (AUC: 0.71 + 0.04), ICP stability (AUC: 0.51 + 0.036) and threshold-based (AUC: 0.5 + 0.02). SIGNIFICANCE:The proposed active learning framework will support real-time ICP-derived analytics by improving precision of artifact-labelling.

SUBMITTER: Megjhani M 

PROVIDER: S-EPMC6681897 | biostudies-literature | 2019 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

An active learning framework for enhancing identification of non-artifactual intracranial pressure waveforms.

Megjhani Murad M   Alkhachroum Ayham A   Terilli Kalijah K   Ford Jenna J   Rubinos Clio C   Kromm Julie J   Wallace Brendan K BK   Connolly E Sander ES   Roh David D   Agarwal Sachin S   Claassen Jan J   Padmanabhan Raghav R   Hu Xiao X   Park Soojin S  

Physiological measurement 20190118 1


<h4>Objective</h4>Intracranial pressure (ICP) is an important and established clinical measurement that is used in the management of severe acute brain injury. ICP waveforms are usually triphasic and are susceptible to artifact because of transient catheter malfunction or routine patient care. Existing methods for artifact detection include threshold-based, stability-based, or template matching, and result in higher false positives (when there is variability in the ICP waveforms) or higher false  ...[more]

Similar Datasets

| S-EPMC9673225 | biostudies-literature
| S-EPMC7577462 | biostudies-literature
| S-EPMC7297990 | biostudies-literature
| S-EPMC5019568 | biostudies-literature
| S-EPMC7889685 | biostudies-literature
| S-EPMC9357215 | biostudies-literature
| S-EPMC3432472 | biostudies-literature
| S-EPMC10799239 | biostudies-literature
| S-EPMC10863000 | biostudies-literature
| S-EPMC9424817 | biostudies-literature