Unknown

Dataset Information

0

Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans.


ABSTRACT: In the clinical photoacoustic (PA) imaging, ultrasound (US) array transducers are typically used to provide B-mode images in real-time. To form a B-mode image, delay-and-sum (DAS) beamforming algorithm is the most commonly used algorithm because of its ease of implementation. However, this algorithm suffers from low image resolution and low contrast drawbacks. To address this issue, delay-multiply-and-sum (DMAS) beamforming algorithm has been developed to provide enhanced image quality with higher contrast, and narrower main lobe compared but has limitations on the imaging speed for clinical applications. In this paper, we present an enhanced real-time DMAS algorithm with modified coherence factor (CF) for clinical PA imaging of humans in vivo. Our algorithm improves the lateral resolution and signal-to-noise ratio (SNR) of original DMAS beamformer by suppressing the background noise and side lobes using the coherence of received signals. We optimized the computations of the proposed DMAS with CF (DMAS-CF) to achieve real-time frame rate imaging on a graphics processing unit (GPU). To evaluate the proposed algorithm, we implemented DAS and DMAS with/without CF on a clinical US/PA imaging system and quantitatively assessed their processing speed and image quality. The processing time to reconstruct one B-mode image using DAS, DAS with CF (DAS-CF), DMAS, and DMAS-CF algorithms was 7.5, 7.6, 11.1, and 11.3?ms, respectively, all achieving the real-time imaging frame rate. In terms of the image quality, the proposed DMAS-CF algorithm improved the lateral resolution and SNR by 55.4% and 93.6?dB, respectively, compared to the DAS algorithm in the phantom imaging experiments. We believe the proposed DMAS-CF algorithm and its real-time implementation contributes significantly to the improvement of imaging quality of clinical US/PA imaging system.

SUBMITTER: Jeon S 

PROVIDER: S-EPMC6710719 | biostudies-literature | 2019 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Real-time delay-multiply-and-sum beamforming with coherence factor for <i>in vivo</i> clinical photoacoustic imaging of humans.

Jeon Seungwan S   Park Eun-Yeong EY   Choi Wonseok W   Managuli Ravi R   Lee Ki Jong KJ   Kim Chulhong C  

Photoacoustics 20190809


In the clinical photoacoustic (PA) imaging, ultrasound (US) array transducers are typically used to provide B-mode images in real-time. To form a B-mode image, delay-and-sum (DAS) beamforming algorithm is the most commonly used algorithm because of its ease of implementation. However, this algorithm suffers from low image resolution and low contrast drawbacks. To address this issue, delay-multiply-and-sum (DMAS) beamforming algorithm has been developed to provide enhanced image quality with high  ...[more]

Similar Datasets

| S-EPMC7065614 | biostudies-literature
| S-EPMC7345629 | biostudies-literature
| S-EPMC8330397 | biostudies-literature
| S-EPMC5059626 | biostudies-literature
| S-EPMC4610852 | biostudies-literature
| S-EPMC5059665 | biostudies-literature
| S-EPMC4595515 | biostudies-literature
| S-EPMC10862394 | biostudies-literature
| S-EPMC6953120 | biostudies-literature
| S-EPMC4114772 | biostudies-literature