Enhanced contrast acoustic-resolution photoacoustic microscopy using double-stage delay-multiply-and-sum beamformer for vasculature imaging.


ABSTRACT: In acoustic-resolution photoacoustic microscopy (AR-PAM) systems, the lateral resolution in the focal zone of the ultrasound (US) transducer is determined by the numerical aperture (NA) of the transducer. To have a high lateral resolution, a large NA is used. However, the larger the NA, the smaller the depth of focus [DOF]. As a result, the lateral resolution is deteriorated at depths out of the focal region. The synthetic aperture focusing technique (SAFT) along with a beamformer can be used to improve the resolution outside the focal region. In this work, for image formation in AR-PAM, we propose the double-stage delay-multiply-and-sum (DS_DMAS) algorithm to be combined with SAFT. The proposed method is evaluated experimentally using hair targets and in vivo vasculature imaging. It is shown that DS_DMAS provides a higher resolution and contrast compared to other methods. For the B-mode images obtained using the hair phantom, the proposed method reduces the average noise level for all the depths by about 134%, 57% and 23%, compared to the original low- resolution, SAFT+DAS and SAFT+DMAS methods, respectively. All the results indicate that the proposed method can be an appropriate algorithm for image formation in AR-PAM systems.

SUBMITTER: Mozaffarzadeh M 

PROVIDER: S-EPMC7065614 | biostudies-literature | 2019 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Enhanced contrast acoustic-resolution photoacoustic microscopy using double-stage delay-multiply-and-sum beamformer for vasculature imaging.

Mozaffarzadeh Moein M   Varnosfaderani Mehdi H H MHH   Sharma Arunima A   Pramanik Manojit M   de Jong Nico N   Verweij Martin D MD  

Journal of biophotonics 20190807 11


In acoustic-resolution photoacoustic microscopy (AR-PAM) systems, the lateral resolution in the focal zone of the ultrasound (US) transducer is determined by the numerical aperture (NA) of the transducer. To have a high lateral resolution, a large NA is used. However, the larger the NA, the smaller the depth of focus [DOF]. As a result, the lateral resolution is deteriorated at depths out of the focal region. The synthetic aperture focusing technique (SAFT) along with a beamformer can be used to  ...[more]

Similar Datasets

| S-EPMC10435476 | biostudies-literature
| S-EPMC6710719 | biostudies-literature
| S-EPMC2966896 | biostudies-other
| S-EPMC4771455 | biostudies-other
| S-EPMC7345629 | biostudies-literature
| S-EPMC6868204 | biostudies-literature
| S-EPMC6688948 | biostudies-literature
| S-EPMC6705424 | biostudies-literature
| S-EPMC3582721 | biostudies-literature
| S-EPMC4759580 | biostudies-literature