Ontology highlight
ABSTRACT:
SUBMITTER: Barrett S
PROVIDER: S-EPMC6731354 | biostudies-literature | 2019 Nov-Dec
REPOSITORIES: biostudies-literature
Barrett Sarah S Thirion Pierre P Harper Dean D Simpkin Andrew J AJ Leech Michelle M Hickey Kim K Ryan Laoise L Marignol Laure L
Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology 20190904 6
<h4>Aim</h4>This study aimed to evaluate the dosimetric impact of uncorrected yaw rotational error on both target coverage and OAR dose metrics in this patient population.<h4>Background</h4>Rotational set up errors can be difficult to correct in lung VMAT SABR treatments, and may lead to a change in planned dose distributions.<h4>Materials and methods</h4>We retrospectively applied systematic yaw rotational errors in 1° degree increments up to -5° and +5° degrees in 16 VMAT SABR plans. The impac ...[more]