Unknown

Dataset Information

0

Architectural Modification of Conformal PEG-Bottlebrush Coatings Minimizes Anti-PEG Antigenicity While Preserving Stealth Properties.


ABSTRACT: Poly(ethylene glycol) (PEG), a linear polymer known for its "stealth" properties, is commonly used to passivate the surface of biomedical implants and devices, and it is conjugated to biologic drugs to improve their pharmacokinetics. However, its antigenicity is a growing concern. Here, the antigenicity of PEG is investigated when assembled in a poly(oligoethylene glycol) methacrylate (POEGMA) "bottlebrush" configuration on a planar surface. Using ethylene glycol (EG) repeat lengths of the POEGMA sidechains as a tunable parameter for optimization, POEGMA brushes with sidechain lengths of two and three EG repeats are identified as the optimal polymer architecture to minimize binding of anti-PEG antibodies (APAs), while retaining resistance to nonspecific binding by bovine serum albumin and cultured cells. Binding of backbone- versus endgroup-selective APAs to POEGMA brushes is further investigated, and finally the antigenicity of POEGMA coatings is assessed against APA-positive clinical plasma samples. These results are applied toward fabricating immunoassays on POEGMA surfaces with minimal reactivity toward APAs while retaining a low limit-of-detection for the analyte. Taken together, these results offer useful design concepts to reduce the antigenicity of polymer brush-based surface coatings used in applications involving human or animal matrices.

SUBMITTER: Joh DY 

PROVIDER: S-EPMC6819148 | biostudies-literature | 2019 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Architectural Modification of Conformal PEG-Bottlebrush Coatings Minimizes Anti-PEG Antigenicity While Preserving Stealth Properties.

Joh Daniel Y DY   Zimmers Zackary Z   Avlani Manav M   Heggestad Jacob T JT   Aydin Hakan B HB   Ganson Nancy N   Kumar Shourya S   Fontes Cassio M CM   Achar Rohan K RK   Hershfield Michael S MS   Hucknall Angus M AM   Chilkoti Ashutosh A  

Advanced healthcare materials 20190325 8


Poly(ethylene glycol) (PEG), a linear polymer known for its "stealth" properties, is commonly used to passivate the surface of biomedical implants and devices, and it is conjugated to biologic drugs to improve their pharmacokinetics. However, its antigenicity is a growing concern. Here, the antigenicity of PEG is investigated when assembled in a poly(oligoethylene glycol) methacrylate (POEGMA) "bottlebrush" configuration on a planar surface. Using ethylene glycol (EG) repeat lengths of the POEGM  ...[more]

Similar Datasets

| S-EPMC7498161 | biostudies-literature
| S-EPMC6424462 | biostudies-literature
| S-EPMC3618222 | biostudies-literature
| S-EPMC7319729 | biostudies-literature
| S-EPMC6645430 | biostudies-literature
| S-EPMC10870754 | biostudies-literature
| S-EPMC6432308 | biostudies-literature
| S-EPMC7183267 | biostudies-literature
| S-EPMC9417478 | biostudies-literature
| S-EPMC9348003 | biostudies-literature