Unknown

Dataset Information

0

Joint B0 and image estimation integrated with model based reconstruction for field map update and distortion correction in prostate diffusion MRI.


ABSTRACT: In prostate Diffusion Weighted MRI, differences in susceptibility values exist at the interface between the prostate and rectal-air. This can result in off-resonance magnetic field leading to geometric distortions including signal stretching and signal pile-up in the reconstructed images. Using a set of EPI data acquired with blip-up and blip-down phase encoding gradient directions, model based reconstruction has recently been proposed that can correct these distortions by using a B0 field estimated from a separate B0 scan. However, change in the size of the rectal air region across time can occur that can result in a mismatch of the B0 field to the EPI scan. Also, the measured B0 field itself can be erroneous in regions of low Signal to Noise ratio around the prostate rectal air interface. In this work, using a set of single shot EPI data acquired with blip-up and blip-down phase encoding gradient directions, a novel joint model based reconstruction is proposed that can account for changes in the off resonance effects between the B0 and EPI scans. For ten prostate patients, using a measured B0 field as an initial B0 estimate, on a 5-point scale (1-5) image quality scores evaluated by an experienced radiologist, the proposed framework achieved scores of 3.50?±?0.85 and 3.40?±?0.51 for b-values of 0 and 500?s/mm2, respectively compared to 3.40?±?0.70 and 3.30?±?0.67 for model based reconstruction. The proposed framework is also capable of estimating a distortion corrected EPI image even without an initial B0 field estimate in situations where a separate B0 scan cannot be obtained due to time constraint.

SUBMITTER: Usman M 

PROVIDER: S-EPMC6837878 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Joint B<sub>0</sub> and image estimation integrated with model based reconstruction for field map update and distortion correction in prostate diffusion MRI.

Usman Muhammad M   Kakkar Lebina L   Matakos Antonis A   Kirkham Alex A   Arridge Simon S   Atkinson David D  

Magnetic resonance imaging 20191023


In prostate Diffusion Weighted MRI, differences in susceptibility values exist at the interface between the prostate and rectal-air. This can result in off-resonance magnetic field leading to geometric distortions including signal stretching and signal pile-up in the reconstructed images. Using a set of EPI data acquired with blip-up and blip-down phase encoding gradient directions, model based reconstruction has recently been proposed that can correct these distortions by using a B<sub>0</sub>  ...[more]

Similar Datasets

| S-EPMC8596522 | biostudies-literature
| S-EPMC4972500 | biostudies-other
| S-EPMC6191883 | biostudies-other
| S-EPMC3316693 | biostudies-other
| S-EPMC4158317 | biostudies-literature
| S-EPMC7170173 | biostudies-literature
| S-EPMC7394453 | biostudies-literature
| S-EPMC7279930 | biostudies-literature
| S-EPMC5860381 | biostudies-literature
| S-EPMC4236106 | biostudies-literature