Unknown

Dataset Information

0

A Strategy of NIR Dual-Excitation Upconversion for Ratiometric Intracellular Detection.


ABSTRACT: Intracellular detection is highly desirable for biological research and clinical diagnosis, yet its quantitative analysis with noninvasivity, sensitivity, and accuracy remains challenging. Herein, a near-infrared (NIR) dual-excitation strategy is reported for ratiometric intracellular detection through the design of dye-sensitized upconversion probes and employment of a purpose-built NIR dual-laser confocal microscope. NIR dye IR808, a recognizer of intracellular analyte hypochlorite, is introduced as energy donor and Yb,Er-doped NaGdF4 upconversion nanoparticles are adopted as energy acceptor in the as-designed nanoprobes. The efficient analyte-dependent energy transfer and low background luminescence endow the nanoprobes with ultrahigh sensitivity. In addition, with the nonanalyte-dependent upconversion luminescence (UCL) excited by 980 nm as a self-calibrated signal, the interference from environmental fluctuation can be alleviated. Furthermore, the dual 808/980 nm excited ratiometric UCL is demonstrated for the quantification of the level of intracellular hypochlorite. Particularly, the intrinsic hypochlorite with only nanomolar concentration in live MCF-7 cells in the absence of exogenous stimuli is determined. Such an NIR dual-excitation ratiometric strategy based on dye-sensitized UCL probes can be easily extended to detect various intracellular analytes through tailoring the reactive NIR dyes, which provides a promising tool for probing biochemical processes in live cells and diagnosing diseases.

SUBMITTER: Ke J 

PROVIDER: S-EPMC6864516 | biostudies-literature | 2019 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Strategy of NIR Dual-Excitation Upconversion for Ratiometric Intracellular Detection.

Ke Jianxi J   Lu Shan S   Shang Xiaoying X   Liu Yan Y   Guo Hanhan H   You Wenwu W   Li Xingjun X   Xu Jin J   Li Renfu R   Chen Zhuo Z   Chen Xueyuan X  

Advanced science (Weinheim, Baden-Wurttemberg, Germany) 20190924 22


Intracellular detection is highly desirable for biological research and clinical diagnosis, yet its quantitative analysis with noninvasivity, sensitivity, and accuracy remains challenging. Herein, a near-infrared (NIR) dual-excitation strategy is reported for ratiometric intracellular detection through the design of dye-sensitized upconversion probes and employment of a purpose-built NIR dual-laser confocal microscope. NIR dye IR808, a recognizer of intracellular analyte hypochlorite, is introdu  ...[more]

Similar Datasets

| S-EPMC7578878 | biostudies-literature
| S-EPMC5146920 | biostudies-literature
| S-EPMC7756657 | biostudies-literature
| S-EPMC4438079 | biostudies-literature
| S-EPMC7069247 | biostudies-literature
| S-EPMC6946702 | biostudies-literature
| S-EPMC5727126 | biostudies-literature
| S-EPMC6001250 | biostudies-literature
| S-EPMC4636449 | biostudies-literature
| S-EPMC6043590 | biostudies-literature