Unknown

Dataset Information

0

Bone healing at non-submerged implants installed with different insertion torques: a split-mouth histomorphometric randomized controlled trial.


ABSTRACT: OBJECTIVES:To evaluate histomorphometrically the healing at implants installed with standard or very low insertion torque values MATERIAL AND METHODS: Twelve volunteer patients were recruited, and two screw-shaped titanium devices were installed in the distal segments of the mandible using insertion torque values of either < 10 Ncm or ~ 30 Ncm. The implants were left to heal in a non-submerged fashion. After 8?weeks, biopsies were retrieved, and ground sections were prepared for histological evaluation. RESULTS:Histological slides from 11 patients were available for (n = 11). The new bone in contact with the implant surface was 39.3 ± 18.5% and 49.4 ± 9.4% at the < 10 and ~ 30 Ncm sites, respectively. Considering the pre-existing old bone, the total mineralized bone was 46.8 ± 22.1% at the < 10 Ncm sites and 57.0 ± 14.1% at the ~ 30 Ncm. No statistically significant differences were found. New bone density and total mineralized bone density were 36.6 ± 8.1% and 53.0 ± 13.5% at the < 10 Ncm sites and 35.9 ± 10.0% and 52.2 ± 16.0% at the ~ 30 Ncm sites, respectively. No statistically significant differences were disclosed. CONCLUSION:From the data of the present study, it can be concluded that a trend of higher osseointegration was observed at the ~ 30 Ncm compared to the < 10 Ncm torque group. Nevertheless, it can be concluded that an implant installed with a very low torque may achieve a good integration. TRIAL REGISTRATION:ClinicalTrials.gov?NCT04017156; trial retrospectively registered on 12 July 2019.

SUBMITTER: Amari Y 

PROVIDER: S-EPMC6893005 | biostudies-literature | 2019 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Bone healing at non-submerged implants installed with different insertion torques: a split-mouth histomorphometric randomized controlled trial.

Amari Yoshiyuki Y   Piattelli Adriano A   Apaza Alccayhuaman Karol Alí KA   Mesa Natalia Fortich NF   Ferri Mauro M   Iezzi Giovanna G   Botticelli Daniele D  

International journal of implant dentistry 20191205 1


<h4>Objectives</h4>To evaluate histomorphometrically the healing at implants installed with standard or very low insertion torque values MATERIAL AND METHODS: Twelve volunteer patients were recruited, and two screw-shaped titanium devices were installed in the distal segments of the mandible using insertion torque values of either < 10 Ncm or ~ 30 Ncm. The implants were left to heal in a non-submerged fashion. After 8 weeks, biopsies were retrieved, and ground sections were prepared for histolog  ...[more]

Similar Datasets

| S-EPMC5518974 | biostudies-literature
| S-EPMC6399089 | biostudies-other
| S-EPMC6917687 | biostudies-literature
| S-EPMC7494466 | biostudies-literature
| S-EPMC7287787 | biostudies-literature
| S-EPMC5563399 | biostudies-literature
| S-EPMC4449187 | biostudies-literature
| S-EPMC7162379 | biostudies-literature
| S-EPMC7019927 | biostudies-literature
| S-EPMC7411779 | biostudies-literature