Unknown

Dataset Information

0

Effects of osseodensification protocol on insertion, removal torques, and resonance frequency analysis of BioHorizons® conical implants. An ex vivo study.


ABSTRACT: Objective:Quantify the effect of the osseodensification Densah® protocol on the insertion torque, ISQ, and the removal torque of conical BioHorizons® implants. Materials and methods:An ex vivo model over fresh pig tibia bone was used. Test group (TG) included 50 osteotomies using Densah® osseodensification protocol, and the control group (CG), 50 osteotomies using BioHorizons®'s recommended procedure. Conical BioHorizons® implants (3.8 × 10.5 mm) were implanted, verifying the insertion torque with a manual torque meter. ISQ values were registered with Ostell® device. Finally, implants were removed with manual reverse torque registering the values. Results were analyzed and compared with the Mann-Whitney test and t-test. Results:Median and interquartile range per group were as follows: insertion torque, CG: 26 (12) Ncm; TG: 42 (26) Ncm, removal torque, CG: 25 (20) Ncm; TG: 40 (28) Ncm, ISQ value, CG: 69.25 (5.5); TG: 71.5 (4). All variables were significantly higher (p ? 0.05) in the osseodensification group. Conclusions:The Osseodensification technique may improve primary stability in the clinical scenario on tapered implants. Further human RCTs are necessary to validate this.

SUBMITTER: Caceres F 

PROVIDER: S-EPMC7494466 | biostudies-literature | 2020 Oct-Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Effects of osseodensification protocol on insertion, removal torques, and resonance frequency analysis of BioHorizons® conical implants. An ex vivo study.

Cáceres Felipe F   Troncoso Cristian C   Silva Ramón R   Pinto Nelson N  

Journal of oral biology and craniofacial research 20200831 4


<h4>Objective</h4>Quantify the effect of the osseodensification Densah® protocol on the insertion torque, ISQ, and the removal torque of conical BioHorizons® implants.<h4>Materials and methods</h4>An ex vivo model over fresh pig tibia bone was used. Test group (TG) included 50 osteotomies using Densah® osseodensification protocol, and the control group (CG), 50 osteotomies using BioHorizons®'s recommended procedure. Conical BioHorizons® implants (3.8 × 10.5 mm) were implanted, verifying the inse  ...[more]

Similar Datasets

| S-EPMC6893005 | biostudies-literature
| S-EPMC9292279 | biostudies-literature
| S-EPMC10460908 | biostudies-literature
| S-EPMC10086841 | biostudies-literature
| S-EPMC7503673 | biostudies-literature
| S-EPMC9601296 | biostudies-literature
| S-EPMC7468011 | biostudies-literature
| S-EPMC7216137 | biostudies-literature
| S-EPMC8432193 | biostudies-literature
| S-EPMC5164966 | biostudies-literature