Unknown

Dataset Information

0

Continuous Digital Monitoring of Walking Speed in Frail Elderly Patients: Noninterventional Validation Study and Longitudinal Clinical Trial.


ABSTRACT: BACKGROUND:Digital technologies and advanced analytics have drastically improved our ability to capture and interpret health-relevant data from patients. However, only limited data and results have been published that demonstrate accuracy in target indications, real-world feasibility, or the validity and value of these novel approaches. OBJECTIVE:This study aimed to establish accuracy, feasibility, and validity of continuous digital monitoring of walking speed in frail, elderly patients with sarcopenia and to create an open source repository of raw, derived, and reference data as a resource for the community. METHODS:Data described here were collected as a part of 2 clinical studies: an independent, noninterventional validation study and a phase 2b interventional clinical trial in older adults with sarcopenia. In both studies, participants were monitored by using a waist-worn inertial sensor. The cross-sectional, independent validation study collected data at a single site from 26 naturally slow-walking elderly subjects during a parcours course through the clinic, designed to simulate a real-world environment. In the phase 2b interventional clinical trial, 217 patients with sarcopenia were recruited across 32 sites globally, where patients were monitored over 25 weeks, both during and between visits. RESULTS:We have demonstrated that our approach can capture in-clinic gait speed in frail slow-walking adults with a residual standard error of 0.08 m per second in the independent validation study and 0.08, 0.09, and 0.07 m per second for the 4 m walk test (4mWT), 6-min walk test (6MWT), and 400 m walk test (400mWT) standard gait speed assessments, respectively, in the interventional clinical trial. We demonstrated the feasibility of our approach by capturing 9668 patient-days of real-world data from 192 patients and 32 sites, as part of the interventional clinical trial. We derived inferred contextual information describing the length of a given walking bout and uncovered positive associations between the short 4mWT gait speed assessment and gait speed in bouts between 5 and 20 steps (correlation of 0.23) and longer 6MWT and 400mWT assessments with bouts of 80 to 640 steps (correlations of 0.48 and 0.59, respectively). CONCLUSIONS:This study showed, for the first time, accurate capture of real-world gait speed in slow-walking older adults with sarcopenia. We demonstrated the feasibility of long-term digital monitoring of mobility in geriatric populations, establishing that sufficient data can be collected to allow robust monitoring of gait behaviors outside the clinic, even in the absence of feedback or incentives. Using inferred context, we demonstrated the ecological validity of in-clinic gait assessments, describing positive associations between in-clinic performance and real-world walking behavior. We make all data available as an open source resource for the community, providing a basis for further study of the relationship between standardized physical performance assessment and real-world behavior and independence.

SUBMITTER: Mueller A 

PROVIDER: S-EPMC6906618 | biostudies-literature | 2019 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Continuous Digital Monitoring of Walking Speed in Frail Elderly Patients: Noninterventional Validation Study and Longitudinal Clinical Trial.

Mueller Arne A   Hoefling Holger Alfons HA   Muaremi Amir A   Praestgaard Jens J   Walsh Lorcan C LC   Bunte Ola O   Huber Roland Martin RM   Fürmetz Julian J   Keppler Alexander Martin AM   Schieker Matthias M   Böcker Wolfgang W   Roubenoff Ronenn R   Brachat Sophie S   Rooks Daniel S DS   Clay Ieuan I  

JMIR mHealth and uHealth 20191127 11


<h4>Background</h4>Digital technologies and advanced analytics have drastically improved our ability to capture and interpret health-relevant data from patients. However, only limited data and results have been published that demonstrate accuracy in target indications, real-world feasibility, or the validity and value of these novel approaches.<h4>Objective</h4>This study aimed to establish accuracy, feasibility, and validity of continuous digital monitoring of walking speed in frail, elderly pa  ...[more]

Similar Datasets

| S-EPMC4015736 | biostudies-literature
| S-EPMC10280686 | biostudies-literature
| S-EPMC4801662 | biostudies-literature
| S-EPMC8177406 | biostudies-literature
| S-EPMC10075311 | biostudies-literature
| S-EPMC6127007 | biostudies-literature
| S-EPMC8872606 | biostudies-literature
| S-EPMC4731975 | biostudies-literature
| S-EPMC4074668 | biostudies-literature
| S-EPMC6093379 | biostudies-literature