Unknown

Dataset Information

0

Machine Learning Techniques Applied to Dose Prediction in Computed Tomography Tests.


ABSTRACT: Increasingly more patients exposed to radiation from computed axial tomography (CT) will have a greater risk of developing tumors or cancer that are caused by cell mutation in the future. A minor dose level would decrease the number of these possible cases. However, this framework can result in medical specialists (radiologists) not being able to detect anomalies or lesions. This work explores a way of addressing these concerns, achieving the reduction of unnecessary radiation without compromising the diagnosis. We contribute with a novel methodology in the CT area to predict the precise radiation that a patient should be given to accomplish this goal. Specifically, from a real dataset composed of the dose data of over fifty thousand patients that have been classified into standardized protocols (skull, abdomen, thorax, pelvis, etc.), we eliminate atypical information (outliers), to later generate regression curves employing diverse well-known Machine Learning techniques. As a result, we have chosen the best analytical technique per protocol; a selection that was thoroughly carried out according to traditional dosimetry parameters to accurately quantify the dose level that the radiologist should apply in each CT test.

SUBMITTER: Garcia-Sanchez AJ 

PROVIDER: S-EPMC6928694 | biostudies-literature | 2019 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Machine Learning Techniques Applied to Dose Prediction in Computed Tomography Tests.

Garcia-Sanchez Antonio-Javier AJ   Garcia Angosto Enrique E   Llor Jose Luis JL   Serna Berna Alfredo A   Ramos David D  

Sensors (Basel, Switzerland) 20191122 23


Increasingly more patients exposed to radiation from computed axial tomography (CT) will have a greater risk of developing tumors or cancer that are caused by cell mutation in the future. A minor dose level would decrease the number of these possible cases. However, this framework can result in medical specialists (radiologists) not being able to detect anomalies or lesions. This work explores a way of addressing these concerns, achieving the reduction of unnecessary radiation without compromisi  ...[more]

Similar Datasets

| S-EPMC7726032 | biostudies-literature
| S-EPMC10857794 | biostudies-literature
| S-EPMC6820559 | biostudies-literature
| S-EPMC9197124 | biostudies-literature
| S-EPMC10413016 | biostudies-literature
2013-01-01 | E-GEOD-29210 | biostudies-arrayexpress
| S-EPMC9876019 | biostudies-literature
| S-EPMC4586339 | biostudies-literature
| S-EPMC7767839 | biostudies-literature
| S-EPMC7674140 | biostudies-literature