Unknown

Dataset Information

0

FRET efficiency measurement in a molecular tension probe with a low-cost frequency-domain fluorescence lifetime imaging microscope.


ABSTRACT: We demonstrate the possibility of measuring FRET efficiency with a low-cost frequency-domain fluorescence lifetime imaging microscope (FD-FLIM). The system utilizes single-frequency-modulated excitation, which enables the use of cost-effective laser sources and electronics, simplification of data acquisition and analysis, and a dual-channel detection capability. Following calibration with coumarin 6, we measured the apparent donor lifetime in mTFP1-mVenus FRET standards expressed in living cells. We evaluated the system's sensitivity by differentiating the short and long lifetimes of mTFP1 corresponding to the known standards' high and low FRET efficiency, respectively. Furthermore, we show that the lifetime of the vinculin tension sensor, VinTS, at focal adhesions (2.30??±??0.16??ns) is significantly (p??<??10??-??6) longer than the lifetime of the unloaded TSMod probe (2.02??±??0.16??ns). The pixel dwell time was 6.8???s for samples expressing the FRET standards, with signal typically an order of magnitude higher than VinTS. The apparent FRET efficiency (EFRETapp) of the standards, calculated from the measured apparent lifetime, was linearly related to their known FRET efficiency by a factor of 0.92 to 0.99 (R2??=??0.98). This relationship serves as a calibration curve to convert apparent FRET to true FRET and circumvent the need to measure multiexponential lifetime decays. This approach yielded a FRET efficiency of 18% to 19.5%, for VinTS, in agreement with published values. Taken together, our results demonstrate a cost-effective, fast, and sensitive FD-FLIM approach with the potential to facilitate applications of FLIM in mechanobiology and FRET-based biosensing.

SUBMITTER: Dumas JP 

PROVIDER: S-EPMC6935677 | biostudies-literature | 2019 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

FRET efficiency measurement in a molecular tension probe with a low-cost frequency-domain fluorescence lifetime imaging microscope.

Dumas John-Paul JP   Jiang James Y JY   Gates Evan M EM   Hoffman Brenton D BD   Pierce Mark C MC   Boustany Nada N NN  

Journal of biomedical optics 20191201 12


We demonstrate the possibility of measuring FRET efficiency with a low-cost frequency-domain fluorescence lifetime imaging microscope (FD-FLIM). The system utilizes single-frequency-modulated excitation, which enables the use of cost-effective laser sources and electronics, simplification of data acquisition and analysis, and a dual-channel detection capability. Following calibration with coumarin 6, we measured the apparent donor lifetime in mTFP1-mVenus FRET standards expressed in living cells  ...[more]

Similar Datasets

| S-EPMC4354599 | biostudies-other
| S-EPMC3356627 | biostudies-literature
| S-EPMC4917836 | biostudies-literature
| S-EPMC7039165 | biostudies-literature
| S-EPMC6816264 | biostudies-literature
| S-EPMC4550514 | biostudies-literature
| S-EPMC4995092 | biostudies-literature
| S-EPMC1366993 | biostudies-literature
| S-EPMC4672317 | biostudies-other
| S-EPMC6457659 | biostudies-literature