Unknown

Dataset Information

0

Impact of local thermal stimulation on the correlation between oxygen saturation and speed-resolved blood perfusion.


ABSTRACT: The physiologically important relationship between oxygen saturation and blood flow is not entirely understood, particularly with regard to the multiple velocity components of flow and temperature. While our previous studies used classic laser Doppler flowmetry combined with an enhanced perfusion probe to assess local blood flow following thermal stimulation, oxygen saturation signals were not assessed. Thus, the current study used multiscale entropy (MSE) and multiscale fuzzy entropy (MFE) to measure the complexity of oxygen saturation signals following thermal stimulation in healthy subjects. The results indicate that thermal stimulation increases oxygen saturation and affects the measured signal complexity in a temperature-dependent fashion. Furthermore, stimulus temperature not only affects the correlation between speed-resolved blood perfusion and oxygen saturation, but also the correlation between the complexity area indices (CAI) of the two signals. These results reflect the complexity of local regulation and adaptation processes in response to stimuli at different temperatures.

SUBMITTER: Wang G 

PROVIDER: S-EPMC6957488 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Impact of local thermal stimulation on the correlation between oxygen saturation and speed-resolved blood perfusion.

Wang Guangjun G   Jia Shuyong S   Liu Mi M   Song Xiaojing X   Li Hongyan H   Chang Xiaorong X   Zhang Weibo W  

Scientific reports 20200113 1


The physiologically important relationship between oxygen saturation and blood flow is not entirely understood, particularly with regard to the multiple velocity components of flow and temperature. While our previous studies used classic laser Doppler flowmetry combined with an enhanced perfusion probe to assess local blood flow following thermal stimulation, oxygen saturation signals were not assessed. Thus, the current study used multiscale entropy (MSE) and multiscale fuzzy entropy (MFE) to m  ...[more]

Similar Datasets

| S-EPMC6550418 | biostudies-literature
| S-EPMC4360981 | biostudies-literature
| S-EPMC7175414 | biostudies-literature
| S-EPMC7443711 | biostudies-literature
| S-EPMC7251192 | biostudies-literature
| S-EPMC8685494 | biostudies-literature
| S-EPMC8342822 | biostudies-literature
| S-EPMC5916916 | biostudies-literature
| S-EPMC7005558 | biostudies-literature
| S-EPMC6987081 | biostudies-literature