Scalable Fabrication of Highly Flexible Porous Polymer-Based Capacitive Humidity Sensor Using Convergence Fiber Drawing.


ABSTRACT: In this study, we fabricated a highly flexible fiber-based capacitive humidity sensor using a scalable convergence fiber drawing approach. The sensor's sensing layer is made of porous polyetherimide (PEI) with its porosity produced in situ during fiber drawing, whereas its electrodes are made of copper wires. The porosity induces capillary condensation starting at a low relative humidity (RH) level (here, 70%), resulting in a significant increase in the response of the sensor at RH levels ranging from 70% to 80%. The proposed humidity sensor shows a good sensitivity of 0.39 pF/% RH in the range of 70%-80% RH, a maximum hysteresis of 9.08% RH at 70% RH, a small temperature dependence, and a good stability over a 48 h period. This work demonstrates the first fiber-based humidity sensor fabricated using convergence fiber drawing.

SUBMITTER: Tousi MM 

PROVIDER: S-EPMC6960705 | biostudies-literature | 2019 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Scalable Fabrication of Highly Flexible Porous Polymer-Based Capacitive Humidity Sensor Using Convergence Fiber Drawing.

Tousi Maryam Mesgarpour MM   Zhang Yujing Y   Wan Shaowei S   Yu Li L   Hou Chong C   Yan Ning N   Fink Yoel Y   Wang Anbo A   Jia Xiaoting X  

Polymers 20191202 12


In this study, we fabricated a highly flexible fiber-based capacitive humidity sensor using a scalable convergence fiber drawing approach. The sensor's sensing layer is made of porous polyetherimide (PEI) with its porosity produced in situ during fiber drawing, whereas its electrodes are made of copper wires. The porosity induces capillary condensation starting at a low relative humidity (RH) level (here, 70%), resulting in a significant increase in the response of the sensor at RH levels rangin  ...[more]

Similar Datasets

| S-EPMC5441428 | biostudies-literature
| S-EPMC5335967 | biostudies-literature
| S-EPMC8630520 | biostudies-literature
| S-EPMC10564641 | biostudies-literature
| S-EPMC8200227 | biostudies-literature
| S-EPMC8198816 | biostudies-literature
| S-EPMC9307709 | biostudies-literature
| S-EPMC9270390 | biostudies-literature
| S-EPMC8469947 | biostudies-literature
| S-EPMC10739884 | biostudies-literature