Unknown

Dataset Information

0

AIE-active non-conjugated poly(N-vinylcaprolactam) as a fluorescent thermometer for intracellular temperature imaging.


ABSTRACT: Since temperature is one of the most significant physiological parameters that dictate the cellular status of living organisms, accurate intracellular temperature measurement is crucial and a valuable biomarker for the diagnosis and treatment of diseases. Herein, we introduce the foremost example of a non-conjugated polymer as a next generation fluorescent thermometer which is capable of addressing the key shortcomings including toxicity and thermal-induced fluorescence quenching associated with ?-? conjugated system-based thermometers developed so far. We revealed, for the first time, the unique photophysical and aggregation-induced emission (AIE) characteristics of well-known thermoresponsive poly(N-vinylcaprolactam) (PNVCL) devoid of any classical fluorophore entity. PNVCL underwent a coil to globular conformational transition in an aqueous medium and appeared to be fluorescent above its lower critical solution temperature (LCST) near body temperature (38 °C). Eventually, this intriguing aspect enabled higher cellular uptake of PNVCL at the LCST boundary. By virtue of the AIE effect, the thermo-induced aggregation phenomenon has been ingeniously utilized to apply PNVCL as a novel fluorescent thermometer for intracellular temperature determination.

SUBMITTER: Saha B 

PROVIDER: S-EPMC7012023 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

AIE-active non-conjugated poly(<i>N</i>-vinylcaprolactam) as a fluorescent thermometer for intracellular temperature imaging.

Saha Biswajit B   Ruidas Bhuban B   Mete Sourav S   Mukhopadhyay Chitrangada Das CD   Bauri Kamal K   De Priyadarsi P  

Chemical science 20191028 1


Since temperature is one of the most significant physiological parameters that dictate the cellular status of living organisms, accurate intracellular temperature measurement is crucial and a valuable biomarker for the diagnosis and treatment of diseases. Herein, we introduce the foremost example of a non-conjugated polymer as a next generation fluorescent thermometer which is capable of addressing the key shortcomings including toxicity and thermal-induced fluorescence quenching associated with  ...[more]

Similar Datasets

| S-EPMC3293419 | biostudies-literature
| S-EPMC4333297 | biostudies-literature
| S-EPMC6905513 | biostudies-literature
| S-EPMC6403691 | biostudies-literature
| S-EPMC7797691 | biostudies-literature
| S-EPMC9313056 | biostudies-literature
| S-EPMC4807691 | biostudies-literature
| S-EPMC8400179 | biostudies-literature
| S-EPMC5789582 | biostudies-literature
| S-EPMC7497634 | biostudies-literature