CLIP: Carbon Dioxide testing suitable for Low power microelectronics and IOT interfaces using Room temperature Ionic Liquid Platform.


ABSTRACT: Health and safety considerations of room occupants in enclosed spaces is crucial for building management which entails control and stringent monitoring of CO2 levels to maintain acceptable air quality standards and improve energy efficiency. Smart building management systems equipped with portable, low-power, non-invasive CO2 sensing techniques can predict room occupancy detection based on CO2 levels exhaled by humans. In this work, we have demonstrated the development and proof-of-feasibility working of an electrochemical RTIL- based sensor prototype for CO2 detection in exhaled human breath. The portability, small form factor, embedded RTIL sensing element, integrability with low-power microelectronic and IOT interfaces makes this CO2 sensor prototype a potential application for passive room occupancy monitoring. This prototype exhibits a wide dynamic range of 400-8000?ppm, a short response time of ~10?secs, and a reset time of ~6?secs in comparison to commercial standards. The calibration response of the prototype exhibits an R2 of 0.956. With RTIL as the sensing element, we have achieved a sensitivity of 29?pF/ppm towards CO2 at ambient environmental conditions and a three times greater selectivity towards CO2 in the presence of N2 and O2. CO2 detection is accomplished by quantifying the capacitance modulations arising within the electrical double layer from the RTIL- CO2 interactions through AC- based electrochemical impedance spectroscopy and DC- based chronoamperometry.

SUBMITTER: Bhide A 

PROVIDER: S-EPMC7018756 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

CLIP: Carbon Dioxide testing suitable for Low power microelectronics and IOT interfaces using Room temperature Ionic Liquid Platform.

Bhide Ashlesha A   Jagannath Badrinath B   Tanak Ambalika A   Willis Richard R   Prasad Shalini S  

Scientific reports 20200213 1


Health and safety considerations of room occupants in enclosed spaces is crucial for building management which entails control and stringent monitoring of CO<sub>2</sub> levels to maintain acceptable air quality standards and improve energy efficiency. Smart building management systems equipped with portable, low-power, non-invasive CO<sub>2</sub> sensing techniques can predict room occupancy detection based on CO<sub>2</sub> levels exhaled by humans. In this work, we have demonstrated the devel  ...[more]

Similar Datasets

| S-EPMC6989144 | biostudies-literature
| S-EPMC6480545 | biostudies-literature
| S-EPMC7435956 | biostudies-literature
| S-EPMC7349509 | biostudies-literature
2010-05-25 | GSE14655 | GEO
| S-EPMC6806188 | biostudies-literature
| S-EPMC7146564 | biostudies-literature
| S-EPMC6449360 | biostudies-literature
| S-EPMC7147171 | biostudies-literature
| S-EPMC5460202 | biostudies-literature