Water-fat Dixon cardiac magnetic resonance fingerprinting.


ABSTRACT: PURPOSE:Cardiac magnetic resonance fingerprinting (cMRF) has been recently introduced to simultaneously provide T1 , T2 , and M0 maps. Here, we develop a 3-point Dixon-cMRF approach to enable simultaneous water specific T1 , T2 , and M0 mapping of the heart and fat fraction (FF) estimation in a single breath-hold scan. METHODS:Dixon-cMRF is achieved by combining cMRF with several innovations that were previously introduced for other applications, including a 3-echo GRE acquisition with golden angle radial readout and a high-dimensional low-rank tensor constrained reconstruction to recover the highly undersampled time series images for each echo. Water-fat separation of the Dixon-cMRF time series is performed to allow for water- and fat-specific T1 , T2 , and M0 estimation, whereas FF estimation is extracted from the M0 maps. Dixon-cMRF was evaluated in a standardized T1 -T2 phantom, in a water-fat phantom, and in healthy subjects in comparison to current clinical standards: MOLLI, SASHA, T2 -GRASE, and 6-point Dixon proton density FF (PDFF) mapping. RESULTS:Dixon-cMRF water T1 and T2 maps showed good agreement with reference T1 and T2 mapping techniques (R2 > 0.99 and maximum normalized RMSE ~5%) in a standardized phantom. Good agreement was also observed between Dixon-cMRF FF and reference PDFF (R2 > 0.99) and between Dixon-cMRF water T1 and T2 and water selective T1 and T2 maps (R2 > 0.99) in a water-fat phantom. In vivo Dixon-cMRF water T1 values were in good agreement with MOLLI and water T2 values were slightly underestimated when compared to T2 -GRASE. Average myocardium septal T1 values were 1129 ± 38 ms, 1026 ± 28 ms, and 1045 ± 32 ms for SASHA, MOLLI, and the proposed water Dixon-cMRF. Average T2 values were 51.7 ± 2.2 ms and 42.8 ± 2.6 ms for T2 -GRASE and water Dixon-cMRF, respectively. Dixon-cMRF FF maps showed good agreement with in vivo PDFF measurements (R2 > 0.98) and average FF in the septum was measured at 1.3%. CONCLUSION:The proposed Dixon-cMRF allows to simultaneously quantify myocardial water T1 , water T2 , and FF in a single breath-hold scan, enabling multi-parametric T1 , T2 , and fat characterization. Moreover, reduced T1 and T2 quantification bias caused by water-fat partial volume was demonstrated in phantom experiments.

SUBMITTER: Jaubert O 

PROVIDER: S-EPMC7064906 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Purpose</h4>Cardiac magnetic resonance fingerprinting (cMRF) has been recently introduced to simultaneously provide T<sub>1</sub> , T<sub>2</sub> , and M<sub>0</sub> maps. Here, we develop a 3-point Dixon-cMRF approach to enable simultaneous water specific T<sub>1</sub> , T<sub>2</sub> , and M<sub>0</sub> mapping of the heart and fat fraction (FF) estimation in a single breath-hold scan.<h4>Methods</h4>Dixon-cMRF is achieved by combining cMRF with several innovations that were previously int  ...[more]

Similar Datasets

| S-EPMC6590362 | biostudies-literature
| S-EPMC3602925 | biostudies-literature
| S-EPMC7755311 | biostudies-literature
| S-EPMC7217066 | biostudies-literature
| S-EPMC10133810 | biostudies-literature
| S-EPMC7677167 | biostudies-literature
| S-EPMC7083689 | biostudies-literature
| S-EPMC6519164 | biostudies-literature
| S-EPMC8818303 | biostudies-literature
| S-EPMC9835035 | biostudies-literature