Navigator-based reacquisition and estimation of motion-corrupted data: Application to multi-echo spin echo for carotid wall MRI.


ABSTRACT: PURPOSE:To assess whether artifacts in multi-slice multi-echo spin echo neck imaging, thought to be caused by brief motion events such as swallowing, can be corrected by reacquiring corrupted central k-space data and estimating the remainder with parallel imaging. METHODS:A single phase-encode line (ky = 0, phase-encode direction anteroposterior) navigator echo was used to identify motion-corrupted data and guide the online reacquisition. If motion corruption was detected in the 7 central k-space lines, they were replaced with reacquired data. Subsequently, GRAPPA reconstruction was trained on the updated central portion of k-space and then used to estimate the remaining motion-corrupted k-space data from surrounding uncorrupted data. Similar compressed sensing-based approaches have been used previously to compensate for respiration in cardiac imaging. The g-factor noise amplification was calculated for the parallel imaging reconstruction of data acquired with a 10-channel neck coil. The method was assessed in scans with 9 volunteers and 12 patients. RESULTS:The g-factor analysis showed that GRAPPA reconstruction of 2 adjacent motion-corrupted lines causes high noise amplification; therefore, the number of 2-line estimations should be limited. In volunteer scans, median ghosting reduction of 24% was achieved with 2 adjacent motion-corrupted lines correction, and image quality was improved in 2 patient scans that had motion corruption close to the center of k-space. CONCLUSION:Motion-corrupted echo-trains can be identified with a navigator echo. Combined reacquisition and parallel imaging estimation reduced motion artifacts in multi-slice MESE when there were brief motion events, especially when motion corruption was close to the center of k-space.

SUBMITTER: Frost R 

PROVIDER: S-EPMC7065122 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Navigator-based reacquisition and estimation of motion-corrupted data: Application to multi-echo spin echo for carotid wall MRI.

Frost Robert R   Biasiolli Luca L   Li Linqing L   Hurst Katherine K   Alkhalil Mohammad M   Choudhury Robin P RP   Robson Matthew D MD   Hess Aaron T AT   Jezzard Peter P  

Magnetic resonance in medicine 20191107 6


<h4>Purpose</h4>To assess whether artifacts in multi-slice multi-echo spin echo neck imaging, thought to be caused by brief motion events such as swallowing, can be corrected by reacquiring corrupted central k-space data and estimating the remainder with parallel imaging.<h4>Methods</h4>A single phase-encode line (k<sub>y</sub> = 0, phase-encode direction anteroposterior) navigator echo was used to identify motion-corrupted data and guide the online reacquisition. If motion corruption was detect  ...[more]

Similar Datasets

| S-EPMC8933245 | biostudies-literature
| S-EPMC8205877 | biostudies-literature
| S-EPMC3320676 | biostudies-other
| S-EPMC2798036 | biostudies-other
| S-EPMC7053244 | biostudies-literature
| S-EPMC5101838 | biostudies-literature
| S-EPMC9576686 | biostudies-literature
| S-EPMC7402028 | biostudies-literature
| S-EPMC2980739 | biostudies-literature
| S-EPMC1345721 | biostudies-literature