Unknown

Dataset Information

0

Comparison of composite and segmental methods for acquiring optical axial length with swept-source optical coherence tomography.


ABSTRACT: This study compared the optical axial length (AL) obtained by composite and segmental methods using swept-source optical coherence tomography (SS-OCT) devices, and demonstrated its effects on the post-operative refractive errors (RE) one month after cataract surgery. Conventional AL measured with the composite method used the mean refractive index. The segmented-AL method used individual refractive indices for each ocular medium. The composite AL (24.52?±?2.03?mm) was significantly longer (P?

SUBMITTER: Goto S 

PROVIDER: S-EPMC7066125 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of composite and segmental methods for acquiring optical axial length with swept-source optical coherence tomography.

Goto So S   Maeda Naoyuki N   Noda Toru T   Ohnuma Kazuhiko K   Koh Shizuka S   Iehisa Ikko I   Nishida Kohji K  

Scientific reports 20200311 1


This study compared the optical axial length (AL) obtained by composite and segmental methods using swept-source optical coherence tomography (SS-OCT) devices, and demonstrated its effects on the post-operative refractive errors (RE) one month after cataract surgery. Conventional AL measured with the composite method used the mean refractive index. The segmented-AL method used individual refractive indices for each ocular medium. The composite AL (24.52 ± 2.03 mm) was significantly longer (P < 0  ...[more]

Similar Datasets

| S-EPMC7775111 | biostudies-literature
| S-EPMC6307737 | biostudies-literature
| S-EPMC3296548 | biostudies-literature
| S-EPMC8253773 | biostudies-literature
| S-EPMC6788676 | biostudies-literature
| S-EPMC4699182 | biostudies-literature
| S-EPMC5804304 | biostudies-literature
| S-EPMC6780333 | biostudies-literature
| S-EPMC4646558 | biostudies-literature
| S-EPMC5955571 | biostudies-literature