Unknown

Dataset Information

0

Dental Implants with Different Neck Design: A Prospective Clinical Comparative Study with 2-Year Follow-Up.


ABSTRACT: The present study was conducted to investigate whether a different implant neck design could affect survival rate and peri-implant tissue health in a cohort of disease-free partially edentulous patients in the molar-premolar region. The investigation was conducted on 122 dental implants inserted in 97 patients divided into two groups: Group A (rough wide-neck implants) vs. Group B (rough reduced-neck implants). All patients were monitored through clinical and radiological checkups. Survival rate, probing depth, and marginal bone loss were assessed at 12- and 24-month follow-ups. Patients assigned to Group A received 59 implants, while patients assigned to Group B 63. Dental implants were placed by following a delayed loading protocol, and cemented metal-ceramic crowns were delivered to the patients. The survival rates for both Group A and B were acceptable and similar at the two-year follow-up (96.61% vs. 95.82%). Probing depth and marginal bone loss tended to increase over time (follow-up: t1 = 12 vs. t2 = 24 months) in both groups of patients. Probing depth (p = 0.015) and bone loss (p = 0.001) were significantly lower in Group A (3.01 vs. 3.23 mm and .92 vs. 1.06 mm; Group A vs. Group B). Within the limitations of the present study, patients with rough wide-neck implants showed less marginal bone loss and minor probing depth, as compared to rough reduced-neck implants placed in the molar-premolar region. These results might be further replicated through longer-term trials, as well as comparisons between more collar configurations (e.g., straight vs. reduced vs. wide collars).

SUBMITTER: Montemezzi P 

PROVIDER: S-EPMC7084739 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dental Implants with Different Neck Design: A Prospective Clinical Comparative Study with 2-Year Follow-Up.

Montemezzi Pietro P   Ferrini Francesco F   Pantaleo Giuseppe G   Gherlone Enrico E   Capparè Paolo P  

Materials (Basel, Switzerland) 20200225 5


The present study was conducted to investigate whether a different implant neck design could affect survival rate and peri-implant tissue health in a cohort of disease-free partially edentulous patients in the molar-premolar region. The investigation was conducted on 122 dental implants inserted in 97 patients divided into two groups: Group A (rough wide-neck implants) vs. Group B (rough reduced-neck implants). All patients were monitored through clinical and radiological checkups. Survival rate  ...[more]

Similar Datasets

| S-EPMC6211599 | biostudies-literature
| S-EPMC7957497 | biostudies-literature
| S-EPMC3538485 | biostudies-literature
| S-EPMC3822308 | biostudies-literature
| S-EPMC8254553 | biostudies-literature
| S-EPMC4485526 | biostudies-literature
| S-EPMC6146902 | biostudies-other
| S-EPMC8718009 | biostudies-literature
| S-EPMC7138872 | biostudies-literature
| S-EPMC7961841 | biostudies-literature