Accuracy Assessment of Molded, Patient-Specific Polymethylmethacrylate Craniofacial Implants Compared to Their 3D Printed Originals.


ABSTRACT: The use of patient-specific implants (PSIs) in craniofacial surgery is often limited due to a lack of expertise and/or production costs. Therefore, a simple and cost-efficient template-based fabrication workflow has been developed to overcome these disadvantages. The aim of this study is to assess the accuracy of PSIs made from their original templates. For a representative cranial defect (CRD) and a temporo-orbital defect (TOD), ten PSIs were made from polymethylmethacrylate (PMMA) using computer-aided design (CAD) and three-dimensional (3D) printing technology. These customized implants were measured and compared with their original 3D printed templates. The implants for the CRD revealed a root mean square (RMS) value ranging from 1.128 to 0.469 mm with a median RMS (Q1 to Q3) of 0.574 (0.528 to 0.701) mm. Those for the TOD revealed an RMS value ranging from 1.079 to 0.630 mm with a median RMS (Q1 to Q3) of 0.843 (0.635 to 0.943) mm. This study demonstrates that a highly precise duplication of PSIs can be achieved using this template-molding workflow. Thus, virtually planned implants can be accurately transferred into haptic PSIs. This workflow appears to offer a sophisticated solution for craniofacial reconstruction and continues to prove itself in daily clinical practice.

SUBMITTER: Chamo D 

PROVIDER: S-EPMC7141183 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy Assessment of Molded, Patient-Specific Polymethylmethacrylate Craniofacial Implants Compared to Their 3D Printed Originals.

Chamo Dave D   Msallem Bilal B   Sharma Neha N   Aghlmandi Soheila S   Kunz Christoph C   Thieringer Florian M FM  

Journal of clinical medicine 20200319 3


The use of patient-specific implants (PSIs) in craniofacial surgery is often limited due to a lack of expertise and/or production costs. Therefore, a simple and cost-efficient template-based fabrication workflow has been developed to overcome these disadvantages. The aim of this study is to assess the accuracy of PSIs made from their original templates. For a representative cranial defect (CRD) and a temporo-orbital defect (TOD), ten PSIs were made from polymethylmethacrylate (PMMA) using comput  ...[more]

Similar Datasets

| S-EPMC8913485 | biostudies-literature
| S-EPMC8395180 | biostudies-literature
| S-EPMC9205921 | biostudies-literature
| S-EPMC7570003 | biostudies-literature
| S-EPMC7805716 | biostudies-literature
| S-EPMC11364008 | biostudies-literature
| S-EPMC7064275 | biostudies-literature
| S-EPMC7557339 | biostudies-literature
| S-EPMC7305828 | biostudies-literature
| S-EPMC7291001 | biostudies-literature