Maxillary Implant-Supported Overdentures: Mechanical Behavior Comparing Individual Axial and Bar Retention Systems. A Cohort Study of Edentulous Patients.


ABSTRACT: Background and objectives: To compare the medium- to long-term mechanical behavior of overdentures with two different retention systems: overdentures with Locator® axial retention, and vertical insertion overdentures with bar retention, used to rehabilitate edentulous maxillar. Material and Methods: This prospective study assessed patients presenting complete maxillary edentulism, rehabilitated by means of implant-supported overdentures (n = 20), 10 with Locator® axial retention (ODA group) and 10 with overdentures on bars (ODB group). Patients also completed a questionnaire to determine their satisfaction with treatment. Results: The mean follow-up time in both groups was 11.4 years, with follow-up times in both groups ranging from 5 to 14 years. The ODA group suffered mechanical complications such as retention loss, need for nylon retention insert changes, resin fracture, and need for relining. In the ODB group, prosthetic dental wear, screw loosening, and complete prosthetic failure were more common. A total of 19 implants failed (23.8%); of these, 11 were in the ODA group (failure rate = 27.5%) and eight in the ODB group (failure rate = 20%). The patient satisfaction questionnaire obtained a mean score of 7.9 out of 10 in the ODA group, and 9.75 in the ODB group. Conclusions: in rehabilitations of edentulous maxillar by means of implant-supported overdentures, both the systems assessed were shown to be effective in the medium to long term. Patients expressed a high level of satisfaction with the treatments received.

SUBMITTER: Manes Ferrer JF 

PROVIDER: S-EPMC7143068 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Maxillary Implant-Supported Overdentures: Mechanical Behavior Comparing Individual Axial and Bar Retention Systems. A Cohort Study of Edentulous Patients.

Mañes Ferrer José Félix JF   Fernández-Estevan Lucía L   Selva-Otaolaurruchi Eduardo E   Labaig-Rueda Carlos C   Solá-Ruíz María Fernanda MF   Agustín-Panadero Rubén R  

Medicina (Kaunas, Lithuania) 20200319 3


<i>Background and objectives:</i> To compare the medium- to long-term mechanical behavior of overdentures with two different retention systems: overdentures with Locator® axial retention, and vertical insertion overdentures with bar retention, used to rehabilitate edentulous maxillar. <i>Material and Methods:</i> This prospective study assessed patients presenting complete maxillary edentulism, rehabilitated by means of implant-supported overdentures (<i>n</i> = 20), 10 with Locator® axial reten  ...[more]

Similar Datasets

| S-EPMC6516946 | biostudies-literature
| S-EPMC6178668 | biostudies-literature
| S-EPMC3860063 | biostudies-literature
| S-EPMC9828494 | biostudies-literature
| S-EPMC5551343 | biostudies-other
| S-EPMC6767521 | biostudies-literature
| S-EPMC6582836 | biostudies-literature
| S-EPMC5024059 | biostudies-literature
| S-EPMC8106178 | biostudies-literature
| S-EPMC5526826 | biostudies-other